179
GB
i
Service
Call Up Service Data
The software version of the operating unit and weather station can be shown on the
display. The Service mode can be called up from the basic settings by holding the
SET
key depressed for 3 seconds. The software version of the operating unit (
)is
displayed first; briefly press the
SET
key to display the software version of the controller
/ weather station (
). The display 10 means Version 1.0, 12 means 1.2, etc. Quit
the service data display by again briefly pressing the
SET
key.
Works Settings
i
On delivery of the ReWiSo controller, the following default settings are stored for
Automatic mode:
◆
Sunshading from sun intensity > 40 kLux
◆
Delay time with sun before sunshading
- Extend: 1 min,
- Retract: 12 min,
◆
Bar until indoor temperature > 18° C
◆
Bar until outdoor temperature > 5° C
◆
Wind alarm from 4 m/s
◆
Rain alarm activated
Содержание 2696