Note:
To prevent repetitive alarming of humidity, there is a
4% tolerance band in humidity alarm. For example, if you set
the high alarm to 60% and silence the alarm, the alarm icon
will continue to flash until the humidity falls below 56%, at
which point, the alarm will reset and must increase above 60%
to activate again.
8.4 Alarm and Key Beeper ON/OFF
In normal mode, press and hold the
ALARM
key for three
seconds to toggle the
BZ ON
(beeper on) or
BZ OFF
(beeper
off) depending on the current setting.
Display console return to normal mode without any operation
in three seconds.
9. Optional Calibration Mode
Note:
The calibrated value can only be adjusted on the
display console.The outdoor remote sensor(s) always displays
the un-calibrated or measured value.
Note:
The measured humidity range is between 10% and
99%. Humidity cannot be accurately measured outside of this
range. Thus, the humidity cannot be calibrated below 10% or
above 99%.
The purpose of calibration is to fine tune or correct for any
sensor error associated with the devices margin of error. The