7. Technical parameters
Tab. 7.1: Technical parameters
Radio parameters
The same as RipEX2 units used
Electrical
100–240 V AC, 50–60 Hz
HW models:
Primary power
36–60 V DC, positive grounding possible
10–30 V DC
18-30 V DC, positive grounding possible
Individual power supply for each RipEX2 unit
Interfaces
4x RJ45,
1x SFP
1× switched 10/100 Base-T Auto MDI/MDIX
1× 10/100/1000 Base-T
1000Base-SX/1000 Base-LX
Ethernet
DB9F
RS232/RS485 SW configurable
COM
300–115 200 bps
N-female(s)
50 Ω
Antenna
HW models
(according to Antenna)
– separate Tx / Rx and Rx, switched
2× N-female
– separate Rx and Tx, separate for each RipEX2 unit
4× N-female
"A" unit alarm, "B" unit alarm, HS controller alarm, "A" and/or "B"
alarm
HW inputs, HW outputs
Environmental
IP40
IP Code (Ingress Protection)
> 900 000 (> 100 years)
MTBF
- 40 to +70 °C (-40 to +158 °F)
Operating temperature
5 to 95 % non-condensing
Humidity
−40 to +85 °C (−40 to +185 °F) | 5 to 95 % non-condensing
Storage
Mechanical
442 W × 392D × 120H mm (17.40 × 15.43 × 4.72 in)
19" rack 3U
Dimensions HS
442 W × 392D × 87H mm (17.40 × 15.43 × 3.42 in)
19" rack 2U
Dimensions RD
442 W × 392D × 87H mm (17.40 × 15.43 × 3.42 in)
19" rack 2U
Dimensions RS
8.9 kg (19.6 lbs), RipEX2 units exl.
Weight HS
12.1 kg (26.7), RipEX2 units incl.
Weight RD
Weight RS
Diagnostic and Management
Standard for individual RipEX2 units used
RipEX2-HS – © RACOM s.r.o.
26
Technical parameters
Содержание RipEX2-HS