1. Safety, environment, licensing
1.1. Frequency
RAy2 microwave links designed for operation in licensed bands must be used in accordance with license
issued by the Telecommunications Authority for the area the device is operating in.
RAy2 microwave links must comply with the maximum permitted radiated power (EIRP) in accordance
with conditions of the given country.
1.2. Safety distance
Safety distances with respect to the US health limits of the electromagnetic field intensity
are in the Minimum Safety Distance tables below, calculated for different antennas and
RAy power levels.
Tab. 1.1: Minimum Safety Distance 11 GHz
+24 dBm RF power
10.700 – 11.700 GHz
RAy2-11
Distance where the FCC limits is met for
Gain G
[dBi]
Parabolic antenna
Antenna code
Occupational /
Controlled Exposure
[cm]
General Population /
Uncontrolled Exposure
[cm]
60
140
29.0
ø 380 mm
JRMA – 380 – 10/11Ra
130
290
36.0
ø 650 mm
JRMA – 650 – 10/11Ra
160
360
38.0
ø 900 mm
JRMB – 900 – 10/11Ra
240
540
41.5
ø 1200 mm
JRMB – 1200 – 10/11Ra
+13 dBm RF power
10.700 – 11.700 GHz
RAy2-11
Distance where the FCC limits is met for
Gain G
[dBi]
Parabolic antenna
Antenna code
Occupational /
Controlled Exposure
[cm]
General Population /
Uncontrolled Exposure
[cm]
30
60
29.0
ø 380 mm
JRMA – 380 – 10/11Ra
50
110
36.0
ø 650 mm
JRMA – 650 – 10/11Ra
60
140
38.0
ø 900 mm
JRMB – 900 – 10/11Ra
90
200
41.5
ø 1200 mm
JRMB – 1200 – 10/11Ra