background image

Содержание PROFI MR160

Страница 1: ......

Страница 2: ...e 13 Conditions of Liability for Defects and Instructions for Safe Operation of Equipment 14 Declaration of Conformity 15 Limitations of Use 16 List of Figures 1 Radio modem MR400 3 3 1 Service connec...

Страница 3: ...iarising users with the parameters of the radio modem its properties modifications and with the parameters of interfaces In order to master all the functions of the radio modem and the MORSE system yo...

Страница 4: ...el raster The receiving and transmitting frequencies are mutually independent and are derived from the frequencies of four Phase Locked Loops programmed by the transceiver microprocessor Channel setti...

Страница 5: ...inimises transient parasite states and optimises bandwidth during switching Switching to the transmitting mode is blocked when the frequency synthesiser is out of lock or the internal temperature exce...

Страница 6: ...io modems RS232 RS422 and RS485 Connectors Table 3 1 Table of data cable connections Terminals RS232 DSUB9F RS422 Canon RS422 1 CTS 8 TxD 7 2 RTS 7 TxD 3 3 RxD 2 RxD 8 4 TxD 3 RxD 2 5 GND 5 GND 5 When...

Страница 7: ...ital outputs Connector D IN digital inputs From left to right 1 input output 1 input output 0 input output 0 input output Terminal UP From left to right if a voltage of 2 4 to 15 V is brought to this...

Страница 8: ...S 85 to 95 OFF OFF ON RSS 95 to 115 OFF OFF OFF RSS 115 POWER ON radio modem is correctly supplied Service Connector The service connector is used for temporary connections of the service cable during...

Страница 9: ...Figure 3 2 View of radio modem description of connectors model with DSUB Canon connectors and with terminalsO 9...

Страница 10: ...108 63 mm including DIN rails 71 mm 184 108 63 mm short version Weight 1 30 kg Antenna connector N female Receiver sensitivity for BER 10 3 Better than 107 dBm Output performance software adjustable 0...

Страница 11: ...5 Dimensional Diagram Figure 5 1 Mechanical dimensions of MR400 11...

Страница 12: ...6 Labelling Radio Modems Figure 6 1 Serial codes of products 12...

Страница 13: ...work however does require permanent maintenance management performed by qualified and trained personnel RACOM and or its authorised partners around the world provide both the training and technical su...

Страница 14: ...maximum permitted output power RACOM is not responsible for products used in an unauthorised way Equipment mentioned in this operator manual may only be used in accordance with instructions contained...

Страница 15: ...rements and other respective measures of regulation 1999 5 EC This equipment therefore bears the CE marking The warning exclamation mark in the circle marks the radio modem as class 2 equipment denoti...

Страница 16: ...cannot be operated without the permission of the respective local radio spectrum administrator who provides a specific frequency for use and issues the appropriate permission for this Important Users...

Страница 17: ...s not available to any user Any commercial use of the software with this licence is strictly forbidden Changes to software and documentation are forbidden RACOM firmware is released with the intention...

Отзывы: