2.1 “Power On” Indicator   

Power On indicator illuminates when utility power’s condition is normal. 

 

 

2.2 

BACKUP

 indicator 

The indicator illuminates when the power is supplied from the batteries. 
 

2.3 “Battery Fault

 Indicator   

This illuminates indicating weak battery. Recharge the battery for at least four hours. If after 
recharging this still illuminates, replace the battery by following the instructions in the 
manual.(You can plug out then check battery) 
 

2.4 Power Switch   

Can be used as the master on/off switch of your equipment by leaving your equipment 
connected to UPS and switched on. 
 

2.5 UPS Outlets     

Provide instantaneous back-up power protection to your equipment. Supply temporary 
uninterrupted operation for your equipment during power failure. 
 

2.6 Bypass Power Sag Outlets 

Provides bypass power sag protection to your equipment. Prevent power problems traveling 
through your system via unprotected peripherals. 
 

2.7 Circuit Breaker Protection 

Serves as an overload and fault protection. This is a critical component of the advanced UPS 
 

2.8 “Phone Jack” Communications Ports   

Telecom transfer ports provide users to extend the applications. 

Caution:

 

To reduce the risk of fire, use only No. 26AWG or larger telecommunication line 

cord. 

 

2.9 communication function 

Provide RS-232 interface and UPSMON software to support NOVELL, UNIX, DOS, 
WINDOWS and other operating systems.   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание 1000VA

Страница 1: ...U P S Uninterruptible Power System Line Interactive Rack Mount Network UPS 600VA 1000VA 1200VA 1500VA 2200VA 3000VA USER S MANUAL...

Страница 2: ...are designed with great care to provide protection within delivery These materials are invaluable if you ever have to return the UPS for service Damage happened during transit is not covered under th...

Страница 3: ...e With the Same Number and Type CAUTION Do Not Dispose of Battery or Batteries in a Fire The Battery May Explode CAUTION Do Not Open or Mutilate the Battery or Batteries Released Electrolyte is Harmfu...

Страница 4: ...2 PRESENTATION Front Panel 600VA 1000VA 1U size Front Panel 1200VA 1500VA 2U size Front Panel 2200VA 3000VA 3U size 2...

Страница 5: ...Back Panel 600VA 1000VA 1U size Back Panel 1200VA 1500VA 2U SIZE 1500VA 110V NO BYPASS OUTPUT 3...

Страница 6: ...Back Panel 2200VA 3U SIZE Back Panel 3000VA 3U SIZE 4...

Страница 7: ...2 5 UPS Outlets Provide instantaneous back up power protection to your equipment Supply temporary uninterrupted operation for your equipment during power failure 2 6 Bypass Power Sag Outlets Provides...

Страница 8: ...electricity e g refrigerator air conditioner copier etc Avoid using extension cords if used make sure they are rated for at least 15 Amps A 3 5 UPS self test UPS will conduct a self test once switched...

Страница 9: ...g to the following illustration Installation with bottom plate Part RMB 05 1 SET Installation with bottom bracket Part RMB 06 1U RMB 07 2U 4U 2 PCS Installation with rear bracket Part RMB 01 1U 02 2U...

Страница 10: ...e Part RMB 08 1U 09 2U 10 3U 11 4U 2 PCS Installation with bottom bracket Part RMB 12 2 PCS Installation with rear bracket Part RMB 13 14 4 PCS Step 1 Step 1 Step 1 Step 2 Step 2 Step 2 Step 3 Step 3...

Страница 11: ...and cause the circuit breaker to trip If the power requirement of your equipment differs from VA convert the requirement power into VA by doing the calculations below 4 2 3 If the power requirement of...

Страница 12: ...1 or COM 2 The other installation instructions and powerful features please refer to READ ME file 5 3 The characteristics of computer interface port The computer interface port has the following char...

Страница 13: ...piece of equipment from the Full time Bypass outlets Switch off UPS wait 5 seconds reset the circuit breaker press down breaker button then switch on UPS Battery undercharged or depleted due to freque...

Страница 14: ...f 9 to 25 of nominal AVR decrease output voltage 13 below input voltage if 9 to 25 of nominal OUTPUT Transfer Time 2 4 milliseconds including detection time EMI RFI filter 10dB at 0 15MHz 50dB at 30MH...

Страница 15: ...Battery Low Rapid beeping sound about 1 824Hz ALARM Overload Continue beeping sound INTERFACE RS 232C port Interface RS 232C Bi directional communication port Ambient Operation 3 500 meters max elevat...

Отзывы: