Disconnecting Hoses 

1.  Stop the hydraulic power source.  
2.  Depressurize the system. 
3.  Allow system and hydraulic fluid to cool.  
4.  Disconnect the supply (pressure) hose to the power source (pressure port) from the tool (IN port).  
5.  Disconnect the return (tank) hose to the hydraulic power source (return port) from the tool (OUT port).  
6.  To prevent contamination, always install dust caps over the hydraulic ports of the tool when 

disconnected.  

Section 3: Tool Operation  

 

Use of this tool on certain materials could generate dust potentially 

containing a variety of hazardous substances such as asbestos, 

silica or lead.  
Inhalation of dust containing these or other hazardous substances 

could result in serious injury, cancer or death. Protect yourself and 

those around you. Research and understand the materials you are 

cutting. 
Follow correct safety procedures and comply with all applicable 

national, state or provisional health and safety regulations relating 

to them, including, if appropriate, arranging for the safe disposal of 

the materials by a qualified person. 

Observe all safety precautions and install the appropriate tool bit for the job if not already installed 
1.  Place the tamper on the surface to be compacted 
2.  The tamper will rise quickly when first turned on. Do not stand over or place any part of your body on 

top of the tamper. Wear safety shoes 

Note:   Partially pressing the trigger allows the tool to run at slow speed, making it easier to 

start or control.

 

3.  Guide the tamper using both hands 

Cold Weather Operation  

If the tie tamper is to be used during cold weather, preheat the system hydraulic fluid at low engine speed. 
When using the normally recommended fluids, oil fluid temperature should be at or above 50° F/10° C 

(400 ssu/82 centistokes) before use. 
Damage to the hydraulic system or tie tamper can result from use with oil that is too viscous or thick. 

 

 

Содержание 910198

Страница 1: ...Racine Railroad Products 1955 Norwood Court Mount Pleasant WI 53403 Phone 262 637 9681 Fax 262 637 9069 Email custserv racinerailroad com racinerailroad com Tie Tamper 910198 Operating Manual...

Страница 2: ...637 9681 Email custserv racinerailroad com racinerailroad com 11 2019 Rev 1 1 Page ii Tie Tamper 910198 Record of Changes Rev No Date Description of Changes Rev 1 7 2019 Initial release Rev 1 1 11 201...

Страница 3: ...ion Declaration 7 Hose Requirements 8 Hose Types 8 Tool to Hydraulic Circuit Hose Recommendations 9 HTMA EHTMA Requirements 10 EHTMA Hydraulic System Requirements 11 Hydraulic Fluid Recommendation 11...

Страница 4: ...our manufacture are warranted against defects in material and workmanship for one year from the date of shipment from our factory When contacting customer service for factory parts service or warrant...

Страница 5: ...mber and not a Racine Railroad Products part number Safety Information For safe installation and operation of this equipment carefully read and understand the contents of this manual Improper operatio...

Страница 6: ...arms and back Always keep hands arms feet head clothing etc out of the operating area and away from all rotating or moving components when operating working on or near this machine Always make sure th...

Страница 7: ...andard 5 GPM input Measured A weighted sound power level Lwa ref 1pW in decibels 106 dBA Uncertainty Kwa in decibels 3 dBA Guaranteed sound power level 109 dBA Measured A weighted sound pressure level...

Страница 8: ...onnect the free ends of the operating hoses together Hose Types Hydraulic hose types authorized for use with the Tie Tamper are 1 Labeled and certified non conductive This is the only hose authorized...

Страница 9: ...The rated working pressure of the hydraulic hose must be at least 2500 psi 173 bar Flow Per Circuit Hose Length Use Inside Diameter Minimum Working Pressure GPM LPM Feet Meter Inch MM PSI Bar Certifi...

Страница 10: ...ection capacity to limit max fluid temperature to at min operating temperature 140 F 60 C 140 F 60 C 140 F 60 C 140 F 60 C Min cooling capacity at a temperature difference of between ambient and fluid...

Страница 11: ...cool operating hydraulic circuits Others that meet or exceeds the specifications of these fluids may also be used Type Hydraulic fluid Chevron Clarity AW 15032 Exxon Univis J 32 Mobil D T E 13M Gulf...

Страница 12: ...ghten securely Tool Connecting Procedures 1 Stop the engine before connecting the tool and or hoses to the OFF power unit and when switching hoses or tools 2 Turn the hydraulic on off valve to the off...

Страница 13: ...derstand the materials you are cutting Follow correct safety procedures and comply with all applicable national state or provisional health and safety regulations relating to them including if appropr...

Страница 14: ...pressure 4 6 GPM 14 23 LPM 1500 2000 psi 106 140 bar TT46233 Model 7 10 GPM 26 38 LPM Couplers or hoses blocked Remove restriction Pressure and return line hoses reversed at ports Be sure hoses are c...

Страница 15: ...ulator charging valve and hand tighten only 4 Advance the valve stem by turning the gauge end clockwise 5 Connect the charge fitting on the hose to the charge valve on the Tester 6 With the gauge and...

Страница 16: ...e tester turn the gauge fully counter clockwise to ensure the stem inside the chuck is completely retracted 3 Thread the tester onto the charging valve of the tool accumulator do not advance the gauge...

Страница 17: ...Support Warranty Technical or Field Service Support Depending upon the circumstances and availability of technical service personnel we may provide technical assistance and or field service support a...

Страница 18: ...910198 Tie Tamper Phone 262 637 9681 Email custserv racinerailroad com racinerailroad com 11 2019 Rev 1 1 Page 18 of 21 Tie Tamper Parts and Assembly...

Страница 19: ...ng 9 1 Seal block 36 2 O ring 10 1 U ring 37 1 Porting block 11 1 O ring 38 1 Automatic valve body 12 1 Rod wiper 39 1 Label 13 1 plug 40 2 Push pin 14 1 Charge valve 41 1 Automatic valve 15 2 Handle...

Страница 20: ...racinerailroad com racinerailroad com 11 2019 Rev 1 1 Page 20 of 21 Seal Kit Parts List Item Quantity Description 4 2 Hose Assembly 6 2 O ring 10 1 U ring 11 1 O ring 12 1 Rod wiper 35 2 Back up ring...

Страница 21: ...910198 Tie Tamper Phone 262 637 9681 Email custserv racinerailroad com racinerailroad com 11 2019 Rev 1 1 Page 21 of 21 Service Parts...

Отзывы:

Похожие инструкции для 910198