OPERATION

When the SBD Timer is set up and aligned 

with T-Links, it is time to race.  The system allows 

ten seconds (10 sec) after the first finish to allow 

the second racer to finish before reseing.  Upon 

completion of the race, the winning lane and 

differential and/or ET will display on the PC (XX.

XXX) an/or the LED Display.

After each race, the timer is locked out for 

ten seconds to allow dirt and dust to settle.

USING SPARE T-LINKS

T-Link  identifier  codes  are  preset  at  the 

factory.    Using  an  external  Reconfig  Jumper 

provided with the backup T-link unit, a T-Link’s 

ID code can be changed enabling a single backup 

unit to replace any unit with the same optimizer 

code.  With the 5820C T-Link, a spare ID ‘Z’ unit 

can be reconfigured as an  ID ‘A’, ‘B’ or ‘C’ unit.  

To temporarily change the ID code of a T-Link 

unit, power the unit off.  Select the Reconfig 

Jumper with the desired ID code and install into 

the T-Port of the T-Link unit to be reconfigured.  

Power on the T-Link unit.  The left LED will flash 

three short times to confirm the T-Link unit has 

been reconfigured to the new ID code.  Unplug 

the Reconfig Jumper and connect any cables to 

the T-Link unit for normal use.  Do not power 

off the T-Link unit after a new ID code has been 

assigned.  The change of ID is temporary.  When 

the T-Link unit is powered off, the ID code will 

revert back to the preset ID shown on the bottom 

of the T-Link unit.

BATTERY CHARGE

Charge the batteries using the external charger 

unit provided by RaceAmerica.  All functional 

electronics are disabled during battery recharge 

to avoid damage.  Typically battery charging will 

take 12 hours.  The charger indicator LED will turn 

from red to green when charging is complete.

Figure 2 - T-Link power and external connections

Power On/RF Transmit

ON - Power ON

Blink - Transmit

RF Receive Status

Blink - Receive

Align Status

Pulsing - Aligned

ON -  NOT aligned

Содержание 5820

Страница 1: ...RaceAmerica Corporation P O Box 3469 Santa Clara CA 95055 3469 408 988 6188 http www raceamerica com info raceamerica com Copyright 2011 RaceAmerica Corporation Rev B Model 5820 The Leader in Event Cr...

Страница 2: ...IREMENTS 4 PRODUCT SPECIFICATIONS 4 AVAILABLE OPTIONS 4 SBD TIMER SETUP 4 TYPICAL TRACK SETUP 5 USING WIN LIGHTS 5 USING PC CAPTURE SOFTWARE 5 OPERATION 6 USING SPARE T LINKS 6 BATTERY CHARGE 6 TECHNI...

Страница 3: ...rranty service during the warranty period should be returned to RaceAmerica with proof of purchase If return of merchandise is by mail the customer agrees to insure the product prepay shipping charges...

Страница 4: ...AILABLE OPTIONS 5890A T Link Battery Charger 3221W Win Lights 3221S Win Light Stands 05 5826 Win Light Sensor Cable 2 req ET Start package 3120AAXWare Derby Data Capture S W 3120B AXWare Derby Race Mg...

Страница 5: ...lly and return to idle state waiting for the next beam to be blocked USING PC SOFTWARE Locate the T Link unit identi ed as ID Z Locate the T Port connector on the back of the T Link unit Connect this...

Страница 6: ...he unit off Select the Recon g Jumper with the desired ID code and install into the T Port of the T Link unit to be recon gured Power on the T Link unit The left LED will ash three short times to con...

Страница 7: ...on with different levels of urgency Errors E1 E3 and E5 indicate local interference effecting the wireless communications or loss of signal These are error messages to alert the user of intermittent i...

Страница 8: ...8 RaceAmerica 5820 Wireless SBD Timer REVISION HISTORY A 05 07 Initial release B 06 11 CORRECT DATA STRINGS C...

Отзывы: