BL4S200 User’s Manual
85
setPWM (continued)
RETURN VALUE
0 — success.
-EINVAL
— invalid parameter value.
-EPERM
— pin type does not permit this function.
-EACCES
— resource needed by this function is not available.
-EFAULT
— internal data fault detected.
positive number — Mode Conflict — the positive number is a bitmap that corresponds
to the pins on a particular block of a RIO chip that have not been configured to support
this function call. Appendix D provides the details of the pin and block associations to
allow you to identify the channels that need to be reconfigured to support this function
call.
SEE ALSO