INSTRUCTIONS

 

T8 LED SIGN TUBE

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install 

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]

IMPORTANT

READ CAREFULLY BEFORE INSTALLING TUBES.  RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.

  

RAB LED tubes must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is 
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON 
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. 

PARTS/COMPONENTS  INCLUDED IN KIT

KIT IS COMPLETE ONLY WHEN ALL PARTS REQUIRED BY THE INSTRUCTIONS ARE PRESENT.

WIRING DIAGRAM

Endcap with L 

mark

AC Input

Connect 

Live wire 

to this side

Connect 

Neutral wire 

to this side

Endcap with N 

mark

- Installation Instructions 10pcs/carton
- LED Lamp 10pcs/carton
- Luminaire Marking Labels 10pcs/carton

WARNINGS:

• 

Risk of electric shock

 - Do not use where directly exposed to water.

• 

Risk of fire or electric shock

 - LED Retrofit Kit installation requires knowledge of sign electrical systems. If not qualified, do not 

attempt installation. Contact a qualified electrician.

• 

 

Risk of fire or electric shock

 - Install this kit only in host signs that have been identified in the installation instructions and where 

 the input rating of the retrofit kit does not exceed the input rating of the sign.

• 

 

Risk of fire or electric shock

 - Installation of this LED retrofit kit may involve drilling or punching of holes into the structure 

 of the sign. Check for enclosed wiring and components to avoid damage to wiring and electrical parts.

• 

Prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.

• 

Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. 
Instead installers should cut existing lampholder leads away from the lampholder and make new electrical connections to 
lampholder lead wires by employing applicable connectors.

• 

Installers  should  examine  all  parts  that  are  not  intended  to  be  replaced  by  the  retrofit  kit  for  damage  and  replace  any 
damaged  parts  prior  to installation of the retrofit kit.

• 

Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm (1/2-in) diameter require a metal 
patch secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed with non-hardening caulk.

SAFETY INFORMATION:

For your and others’ safety, please read the precaution carefully before installation:
- Always keep AC supply off during installation.

- The light source contained in this luminaire shall only be replaced by the manufacturer, its service agent, or a similar qualified person.
- Not for use with dimmers.
- This product is not intended for use with emergency exits.
- Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

- The electrical rating is 120-277Vac, the installer must determine whether they have 120-277Vac at the luminaire before installation.

GENERAL PURPOSE
RETROFIT SIGN
CONVERSION

FOR USE ONLY
IN ACCORDANCE WITH
KIT INSTRUCTIONS

KIT IS COMPLETE ONLY WHEN ALL PARTS
REQUIRED BY THE INSTRUCTIONS ARE PRESENT

Содержание T8

Страница 1: ...shock Installation of this LED retrofit kit may involve drilling or punching of holes into the structure of the sign Check for enclosed wiring and components to avoid damage to wiring and electrical parts Prevent wiring damage or abrasion do not expose wiring to edges of sheet metal or other sharp objects Installers should not disconnect existing wires from lampholder terminals to make new connect...

Страница 2: ...ill need to be relocated and mounted to a visible location on the sign Make sure the electrical rating of the switch or circuit breaker is not exceeded See Mounting Instructions for Disconnect Switch 6 Confirm that power is still disconnected from fixture and fixture is properly grounded 7 Follow the step below to install single lamp or multiple lamps Single Lamp Multiple Lamps 8 Complete all elec...

Страница 3: ...Fig 3 12 Rotate the tubes from 0 to 90 to get the best illumination Fig 4 Fig 4 13 Reinstall diffuser if applicable to complete the assembly Fig 5 INSTALLATION INSTRUCTIONS Cont d Fig 5 Base Board R17D Lamp Holder Follow the measurements on Table 1 INSTALLATION INSTRUCTIONS Cont d MOUNTING INSTRUCTIONS FOR DISCONNECT SWITCH IF APPLICABLE 14 Apply power to fixture and check for illumination 1 Insta...

Страница 4: ...ians to install and end users to save energy We d love to hear your comments Please call the Marketing Department at 888 RAB 1000 or email marketing rablighting com DIMENSIONAL DRAWING inch ACCESSORY INSTALLATION CABLE KIT 1 Attach the Magnetic Mounting Bracket to the top of the inside of the light box 2 Adjust the Self Clamping Tension Lock up or down the Cable Wire according to your preferred he...

Отзывы: