HOW DO THE SCANNING LED DETECTION
INDICATORS WORK?
Scanning LEDs serve as a deterrent by indicating a security device
in operation. They also show the STL360’s mode of operation.
Automatic Mode
When the STL360 is “On Guard” in Auto mode, three red LEDs scan
continuously day and night, except during detections
(at which time
the controlled lights will go on and LEDs will be off)
.
Test Mode
When the sensor is in “Test Mode” all of the LEDs will be off.
Manual Override Mode
When the sensor is ready for “Manual Override Mode” the middle
LED will be on steady.
Evening Timer Mode
When the sensor is ready for “Evening Timer Mode Mode” the
middle LED will be blink.
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
CAUTION: TURN OFF ALL POWER AT CIRCUIT BREAKER/FUSE PANEL. The total lighting load connected to Stealth must
not exceed 8 amps 277V
(LED load)
. To switch more wattage an electrician can install a relay. Line Carrier Remote Control
Systems such as X-10 or Leviton are incompatible with sensors and cause false activations.
DO NOT INSTALL SENSORS ON A CIRCUIT THAT FEEDS MOTOR LOADS LIKE KITCHEN APPLIANCES, HVAC EQUIPMENT,
WASHER/DRYER, OR GARAGE DOOR OPENERS. Sensor must be below and as far as possible away from lights. Sensor
functions best when the direction of expected movement is across its detection pattern, not towards the sensor. Mount
6–12 feet high for optimum range and detection.
STL360HB/L
STL360H/L
“On Guard Auto Mode”
LEDs scan continuously back & forth
“Test Mode” all LEDs off
Middle LED on
steady
is Manual Override Mode
Middle LED
blinking
is Evening Timer Mode