TROUBLESHOOTING CHECKLIST
Check that:
1. Proper lamp is installed. Lamp is not faulty.
2. Line voltage at the fixture is proper.
MEGAFLOOD INSTALLATION INSTRUCTIONS
(continued)
© RAB Electric, 9358-0, 11/04
THESE INSTRUCTIONS
DO NOT
COVER ALL DETAILS OR
VARIATIONS IN EQUIPMENT, NOR DO THEY PROVIDE FOR
EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNEC-
TION WITH INSTALLATION, OPERATION OR MAINTENANCE.
Easy Installation & Product Help
Fax Back
Tech Help Line
Faxed Tips & Specs,
Call our friendly experts.
24 hours/day.
8AM - 5PM ET Mon. - Fri.
888 RAB-1236
888 RAB-1000
www.rabweb.com
Visit our internet site for
Your questions and requests
color product photos
will be answered promptly.
and installation tips.
RAB LIGHTING
170 Ludlow Avenue Northvale, New Jersey 07647 U.S.A.
RA
B
MAKES
IT
EASY!
BALLAST VOLTAGE
This fixture is normally equipped with a quad tap ballast and
is factory set to 277 volts. If 120, 208 or 240 volts is desired,
relocate power tap to appropriate voltage. (This fixture is
NOT suitable for 480 volt circuits). When this fixture is
supplied with a single voltage tap, make sure the voltage
furnished to the fixture is the same as specified on the unit.
CAUTION: Make sure all unused ballast taps are capped to avoid a short circuit to the reflector when the fixture
is energized.
SOCKET ADJUSTMENT
WARNING: Make certain power is off before installing
or maintaining fixture
The MegaFlood socket can be moved to the rear position
to fine tune the beam spread to the application. The rear
position provides a narrow beam, the center position
(standard) provides a medium beam spread.
To move the socket:
Remove the two screws holding the socket.
Move socket and replace screws.
Reinstall socket bracket.
REPLACEMENT LAMPS
Metal Halide
ANSI
High Pressure Sodium ANSI
Wattage
Catalog #
Code
Wattage
Catalog #
Code
175
LMH175
M57
250
LHPS250
S50
250
LMH250
M58
400
LHPS400
S51
400
LMH400
M59
RE-LAMPING
WARNING: Make certain power is off before installing
or maintaining fixture
Open fixture by loosening the four captive door screws.
Swing lens door down on hinges.
Caution:
Prior to installing, check that the lamp is of proper
type and wattage. Observe lamp manufacturer’s recommen-
dations on lamp operation, ballast type and burning positions.
CLEANING
Clean reflector and lens with nonabrasive glass cleaning
solution or detergent. Rinse with clean water.
Caution: Be sure fixture temperature is cool enough
to touch.
OPTIONS AND ACCESSORIES
Photocell:
1. Knockout or drill out appropriate hole in casting.
2. Insert threaded end of control through gasket and cast-
ing knock-out hole. Secure from inside of casting with
locking nut.
3. Make sure wire leads on photocontrol are rated for 150
degrees C.
Vandal Resistant Lexan Shield:
1. This lens simply screws into the four standoffs located
on the front of the fixture lens door. The Lexan shield is
attached to the standoffs with screws provided.
3. Fixture is wired properly.