ALED
TM
POLE MOUNT INSTRUCTIONS
ALED-IN-0311 9524-0
ROUND POLE ADAPTOR
ACCESSORY
For use with standard RAB pole drilling.
1.
Drill round pole using the dimesions shown below in the Pole Drilling Detail.
2.
Trim
Adaptor Gasket
supplied with ALED
.
3.
Fixture Bolt
may not be long enough as originally supplied with ALED. A longer
Fixture Bolt
is supplied with the RPA
LED kits.
4.
Changing
Fixture Bolt
(if necessary):
a. Open the fixture door
b. Remove ALED Adaptor bracket from fixture
c. Change
Fixture Bolt
and re-assemble
5.
Place
Round Pole Adaptor
and
RPA Gasket
between the fixture and drilled
Pole
as shown. Line up top holes of the
Gaskets
and
Round Pole Adaptor
with top hole in the pole drilling pattern.
6.
Place 3/8-16
Fixture Bolt
from the
ALED
thru the top hole of the RPA and Gaskets to the Round
Pole
. Use nut,
lockwasher and washer and tighten inside the pole.
7.
Feed wires through larger bottom hole. Make the necessary wiring connections and knot the wires for strain relief.
8.
Install the pole cap.
Round Pole
(not supplied)
Fixture Bolt
Adaptor Gasket
(trimmed)
Round Pole
Adaptor
RPA Gasket