Walk Test:
The purpose of the Walk Test is
to check and adjust the coverage
pattern. STEALTH has a 5 minute Test
Period which allows the sensor to be
aimed and walk-tested day or night.
If you require 5 more minutes of
Test Time, turn the power off for at
least 10 seconds and back on again.
During the Test Period, the sensor
will keep lights on for 5 seconds
each time it detects movement in
its Detection Zone. The sensor will
change to Automatic Mode after 5
minutes of testing.
To enter test mode:
Turn power off for at least 10
seconds and back on again.
1. Aim the sensor across the traffic
pattern you want to detect. Start
by aiming the sensor downward
and then raise it slowly until the
desired range is obtained.
2. Start outside the pattern and
walk across pattern until lights
go on. As distance from the
sensor increases, it will take
more movement to be detected.
Aiming and Walk Testing
Start
Finish
3. Adjust the sensor aiming as
needed to improve coverage.
4. To adjust sensitivity, turn knob
gently. Less sensitivity (counter-
clockwise) may be desired if you
wish to detect a limited area or if
the sensor is being activated by
wind, foliage, or animals. More
sensitivity (clockwise) will help
cover a larger area.
5. Repeat steps 2-4 until you are
satisfied with coverage.
6. “Time” is factory set at 5-8
minutes. This period starts after
the movement in the detection
pattern ceases. Turn the time
control counterclockwise for
less time and clockwise for more
time.
7. STEALTH is factory set for
night-only operation. To obtain
24-hour operation, turn the
photocell control full counter-
clockwise. Intermediate settings
will adjust operation during
dawn and dusk.
8. Your sensor is ready for
operation. See “Technical Tips” on
pages 7-11 for additional help.