background image

LOS800CA Smart Switch requires
no maintenance other than keeping 
the lens area clean and free of 
obstructions. Do not attempt to open 
or repair the unit. There are dangerous 
voltages inside the case and no user 
serviceable parts.
Your LOS800CA will be replaced or 
repaired, at our option, if it proves 
to be defective in workmanship or 
materials within one year from the 
date of original purchase. 
For repair or replacement, return the 
product freight prepaid and insured 
to the address below. The LOS800CA 
should be packed carefully. Please 
include your sales receipt and a 
description of the problem. 

If your unit is out of warranty or the 
damage is unrelated to its original 
manufacture, return your unit directly to 
RAB with a check for $20.00 (payable 
to RAB Lighting). We will repair or 
replace the unit.
Under no circumstances shall we 
be liable for any incidental or conse-
quential damages arising out of or 
in connection with the use or perfor-
mance of this product or other 
indirect damages with respect to 
loss of property or revenue or cost of 
installation, removal or reinstallation. 
This warranty gives you specific legal 
rights and you may also have other 
rights which vary from state to state. 

8

Limited Warranty

Easy Installation & Product Help

LOS800CA-IN-0708

Содержание LOS800CA

Страница 1: ...meone enters the room Covers 1000 square feet eliminates the need for multiple sensors Superb small movement sensitivity within 18 feet Great for sedentary office use No dead spots within 18 zones Easy Installation Works with electronic ballasts No minimum load requirement Replaces single pole wall switches without additional wiring Decorator style rectangular switch plate included Only 1 2 protru...

Страница 2: ...e sensor s detection zone may be restricted by covering a portion of the lens with a white paper label or tape Sensor has view of adjacent area Wiring Replaces single pole wall switch 3 wire system where neutral hot are present Temperature Range 4 F to 104 F 20 C to 40 C Humidity Range 93 relative humidity Approvals UL Listed Photocontrol UL Standard 773A Weight 3 3 oz no box 5 oz with box Parts L...

Страница 3: ...e On button the LED will be Green and the sensor will enter Auto Mode When it detects movement the LED alternates between Red and Green and the lights will turn on 7 When detection stops the sensor turns off the lights in about 8 seconds while set at minimum 8 Check coverage area 9 Set the timer to desired amount from 5 seconds to 15 minutes 10 After the lights go out and the sensor does not detec...

Страница 4: ... 5 Troubleshooting Lights Do Not Turn On 1 Check that the lamps and fixtures work wiring exactly matches the wiring diagram wiring polarity is correct power is on sensor has warmed up for 40 secs 2 Make sure sensor s view of the room is not blocked Lights Do Not Turn Off 1 Check that the Time delay control is set to minimum 2 Stay completely out of the protection pattern to avoid activation 3 Make...

Страница 5: ...ease include your sales receipt and a description of the problem If your unit is out of warranty or the damage is unrelated to its original manufacture return your unit directly to RAB with a check for 20 00 payable to RAB Lighting We will repair or replace the unit Under no circumstances shall we be liable for any incidental or conse quential damages arising out of or in connection with the use o...

Отзывы: