background image

Note: This device has been tested and found to comply with the 
limits for Class B digital devices pursuant to Part 15 Subpart B, of the 
FCC rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential environment. This 
equipment generates, uses, and can radiate radio frequency energy, 
and if not installed and used in accordance with the instruction 
manual, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is 
encouraged to try and correct the interference by one or more of 
the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from 
  that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
To comply with the FCC’s RF exposure limits for general population / 
uncontrolled exposure, this transmitter must be installed to provide 
a separation distance of at least 20 cm from all persons and must not 
be co-located or operating in conjunction with any other antenna or 
transmitter. The manufacturer is not responsible for any radio or TV 
interference caused by unauthorized modifications to this equipment. 
Such modifications could void the user’s authority to operate the 
equipment.
CAUTION: Changes or modifications to this equipment not expressly 
approved by RAB Lighting may void the user’s authority to operate 
this equipment.

Содержание Lightcloud HID-54S-EX39-8TW-BYP/LCBR

Страница 1: ...1 844 LIGHTCLOUD 1 844 544 4825 WE RE HERE TO HELP Welcome HID 54S EX39 8TW BYP LCBR Field Adjustable HID Replacement Lightcloud with 5 Pin Lightcloud Blue Port...

Страница 2: ...any other device eliminating the need for a Gateway or Hub and maximizing the control system s reach Product Features Wireless control from your mobile device On off and dimming Wireless remote contr...

Страница 3: ...A FREE STANDING PORTABLE LUMINAIRE USE ONLY WITH A PORTABLE LUMINAIRE THAT IS PROVIDED WITH A SHADE Only install in operating environments between 22 F and 140 F 30 C to 60 C Only use the control prov...

Страница 4: ...ed the input rating of the luminaire Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation WARNING To prevent wiring damage or abrasion do not...

Страница 5: ...e location Turn off power OFF OFF WARNING Place the wall switch in the off position Lightcloud Blue devices should be positioned within 60 ft of each other Building materials such as brick concrete an...

Страница 6: ...allast or disconnect from existing lampholder Remove and dispose of ballast in correct manner Shown as Figure 1 North America 120 277VAC 3 AC 120 277V Capacitor Ballast Ignitor Reconnect directly to t...

Страница 7: ...rectly earth Attach retrofit label to luminaire North America 120 277VAC Securely fasten the earth fly lead cable to the main body structure If the cable are damaged in any way please replace Do not u...

Страница 8: ...first time use the lamp will be ready to pair to the Lightcloud Blue app Power on the lamp to enter pairing mode While pairing the lamp will flash on off 5x and then dim and flash on off 3x to indicat...

Страница 9: ...d the Lightcloud Blue app from the Apple App Store or Google Play store Tap the add device icon in the app to start connecting devices Follow the remaining steps in the app Create areas groups and sce...

Страница 10: ...ely Do not allow less than 1 second and more than 10s elapse before switching off and keep off for at least 3s before switching on The lamp will flash 3 times then reset to 100 brightness at default C...

Страница 11: ...on Bad connection Faulty switch Power is off Discontinue use immediately Check wiring connections Test switch or replace it Verify power supply is on Call an electrician Troubleshooting DO NOT use sol...

Страница 12: ...e performed using the Lightcloud Blue app Configuration FCC Information This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not ca...

Страница 13: ...ce by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit diff...

Страница 14: ...pid Provisioning technology devices can be quickly and easily commissioned for residential and large commercial applications using the Lightcloud Blue mobile app Each device in a system can communicat...

Отзывы: