FFLED 120W INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
®
0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V thru 277V,
50 or 60 Hz. Units ordered with (/480V) suffix are 480V, 50Hz
or 60Hz. For 0-10V Dimming, follow the wiring directions as
below.
1.
Connect the black fixture lead to the LINE supply lead.
2.
Connect the white fixture lead to the COMMON supply
lead.
3.
Connect the GROUND wire from fixture to supply ground.
4.
Connect the purple fixture lead to the (V+) DIM lead.
5.
Connect the gray fixture lead to the (V-) DIM lead.
6.
Cap the yellow fixture lead, if present. Do NOT connect.
NOTE: Do not connect DIM V+ (purple)/ DIM V- (gray) to
line voltage or supply ground.
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough
to touch. Do not clean or maintain while fixture is
energized.
1.
Lens should be washed in a solution of warm water and
any mild, non abrasive household detergent, rinsed with
clean water and wiped dry. Do not use chemicals to clean
fixture
.
2.
Do not open the fixture to clean the LED. Do not touch
the LED.
TROUBLESHOOTING
1. Check that the line voltage at the fixture is correct. Refer
to wiring directions.
2. Be sure the fixture is grounded properly.
3. Is the photocell, if used, functioning properly?
SURGE PROTECTOR OPTION
Units ordered with (/SP) suffix are provided with 10kV surge
protector secured within the fixture. Follow wiring directions as
below -
1.
Connect the black fixture lead to the LINE supply lead and
black surge protector wire.
2.
Connect the white fixture lead to the COMMON supply lead
and white surge protector wire.
3.
Connect the GROUND wire from fixture to supply ground
and green surge protector wire.
4.
Connect the purple fixture lead to the (V+) DIM lead.
5.
Connect the gray fixture lead to the (V-) DIM lead.
NOTE: Do not connect DIM V+ (purple)/ DIM V- (gray) to line
voltage or supply ground.
SURGE
PROTECTOR