32
support.R82.org
Power unit
For an optimum lifetime the power unit must
be connected to the mains voltages as often as
possible (e.g. every night). Charge the batteries 12
hours before use.
The batteries must be charged at least every 3rd
month - otherwise there might be damages due to
self-discharge. It is recommended to test the battery
function at least once every year.
Recharging the battery:
• Plug the charging lead into the handset
• Plug the charger into the electricity supply and
switch ON. A yellow light on the charger will
light up
• Charge the batteries until the lamp on the
charger turns green
Warning
Caregiver
• Do not leave children and youngsters alone
with the handset
•
Do not let children and youngsters play with the
handset
•
Do not leave the handset within reach of
children and youngsters.
• It is important to remove the transport plastic
bag before using the handset. Cables need to
be placed in such a way that users or carers
cannot trip and injure themselves.
Product
•
The power unit does not have a safety stop
•
The system must not be sprayed directly with a
highpressure cleaner
•
Cleaning with a steam cleaner is not permitted
•
Do only use the power unit within specified
working limits
• It is recommended to check the handset and
cable for damage and holes caused by violent
handling at least once a year
•
Do not submerge the handset in water
•
Do not attempt to repair any part of the power
unit.
Technical Data
Battery - BA18
• Capacity 1.3 Ah - 24V DC
• Charging current is max. 500 mA
•
IPX6
• Duty cycle: Max. 10% or 2 min. use then 18
min. without use
The batteries have a maximum life of 4 years but this
can vary depending upon the conditions of use and
charging practices
Battery charger - CH01
•
Mains: 100 - 240VAC/50-60 Hz switch mode
•
Charging voltage: 27.6 VDC
• Charging current: Max. 500 mA
Actuator - LA28/LA32
• Input voltage: 24V
•
Noise level: ≤ 45 dB(A)
•
IPX5
Handset - HB 40
•
IPX1
Detachable parts
• Handset - HB 40
• Battery - BA 18
Applied part
• Handset - HB 40
IP-Rating table
IPX0
No protection
IPX1
Protection against vertically falling
drops of water e.g. condensation
IPX2
Protection against direct sprays of
water up to 15° from the vertical
IPX3
Protected against direct sprays of water
up to 60° from the vertical
IPX4
Protection against water sprayed from
all directions - limited ingress permitted
IPX5
Protected against low pressure jets
of water from all directions - limited
ingress
IPX6
Protected against temporary flooding
of water, e.g. for use on ship decks -
limited ingress permitted
IPX7
Protected against the effect of immer-
sion between 15 cm and 1 m
IPX8
Protects against long periods of immer-
sion under pressure
HB40
LA28/LA32
BA18
EN
Содержание High-low
Страница 4: ...4 support R82 org 1 05 4 5 3 6 2 ...
Страница 5: ...5 support R82 org 05 8 7 ...
Страница 6: ...6 support R82 org 05 1 4 5 3 2 ...
Страница 7: ...7 support R82 org 05 1 4 5 3 2 ...
Страница 8: ...8 support R82 org 2 3 4 05 5 1 ...
Страница 9: ...9 support R82 org 05 2 4 3 1 5 ...
Страница 10: ...10 support R82 org 2 4 3 Size 1 2 1 1 2 1 2 0 30 10 20 6 5 ...
Страница 11: ...11 support R82 org 7 9 8 ...
Страница 12: ...12 support R82 org 2 3 5 4 Size 3 1 ...
Страница 13: ...13 support R82 org 2 4 3 1 5 ...
Страница 14: ...14 support R82 org 3 2 5 6 4 1 ...
Страница 15: ...15 support R82 org 3 2 1 ...
Страница 16: ...16 support R82 org 2 3 5 4 1 ...
Страница 17: ...17 support R82 org 2 3 5 4 1 ...
Страница 18: ...18 support R82 org 17 mm 17 mm 3 2 4 1 ...
Страница 19: ...19 support R82 org 4 4 ...
Страница 138: ...support R82 org ...