9.5 UP/DOWN Power option (software only)
The UP/DOWN Power option modifies the function of receiving signals present
on the telemetry connector.
Specifically, the on and off control signals of the RF section become control signals
of the emitted RF power level, allowing UP/DOWN adjustment.
The UP or DOWN command is provided by connecting the relative signal on the
connector to ground for at least 500mS (the pin has an internal pull-up towards
the power supply).
Configuration of the DB15F telemetry connector (Remote):
Pin Standard Function
UP/DOWN Power Function
14 On cmd
Up cmd
Enables the RF power delivered Increases the RF power delivered
15 Off cmd
Down cmd
Disables the RF power delivered Reduces the RF power delivered