10
/ 36
User Manual
Rev. 1.0 - 27/05/21
TEX1703TFT
TEX1703TFT
@ 230 Vac
Main fuse
(2x) F 16A type 6x30
Table 5.1:
Fuses
5.1.2 Placement of the device
Useful tips for correct installation:
• Avoid the presence of external elements near the ventilation inlets and outlets,
as they could prevent proper ventilation of the device.
• Avoid proximity to a source of heat or flammable gas.
• Limit places subject to accumulation of humidity, dust, sand or salt or
environments that could compromise correct operation of the equipment.
• Avoid installing the equipment in inhabited places due to possible noise pollution,
or on lightweight supports. The device may hum during operation due to forced
ventilation. The mounting surface must be able to withstand the weight of the
device and must be solid.
Note:
below we will refer to a complete station of which the device can form a part.
The same procedures also apply if the device is used as a standalone one.
The device is generally connected inside a 19” rack and fixed with M5 screws in
the designated holes.
The device must be installed at least 1 metre from the ground.
Install the rack where the transmitter will be operated. The rack is mounted on
wheels for ease of movement: once it is put into position it is advisable, therefore,
to use the four screws at the base of the rack to stabilize it perpendicular to the
ground.
The environment where the rack is installed should be air conditioned at about
25 °C and equipped with a filter for the elimination of dust and salt.
Содержание TEX1703
Страница 1: ...TEX1703 TEX1703TFT TFT USER MANUAL VOLUME1 Manufactured by R V R ELETTRONICA Italia ...
Страница 41: ...TEX1703TFT 35 36 User Manual Rev 1 0 27 05 21 9 4 Option CNT7 8 150 R F OUTPUT Type 7 8 50Ω ...
Страница 42: ...36 36 User Manual Rev 1 0 27 05 21 TEX1703TFT This page was intentionally left blank ...