Note  : 

If  you  intend  to  connect  it  directly  to  a  PC,  it  is  necessary  to  use  a 

crossover ethernet cable. This is a basic prerequisite to ensure equipment correct 

operation.

3)  Connect  the  network  cable  to  the  relevant 

POWER

  connector  on TCP/IP 

interface.

  5.2  First Power-On and Set-Up

Perform this procedure upon first power-up and each time you make changes to 

the configuration this component is integrated into.

  5.2.1  Web User Interface (WUI)

Once all connections previously described are performed, the equipment is ready 

for commissioning.

The 

WUI

  (Web  User  Interface)  allows  you  to  adjust,  modify  or  display  the 

configuration variables and operation data. Follow the procedure below to open 

the 

WUI

.

1)  Open your web browser on your PC, and connect to 

http://192.168.0.244

 to 

connect to the 

WUI

 (if LAN IP address was previously modified, it is necessary 

to use the new one). The following page opens:

User Name 
Password

Login

Menu 1

      

Note : 

If address

 http://192.168.0.244

 

does not work, check and set IP address as 

192.168.0.XXX

 (where XXX is a figure between 0 and 255, excluding 244 that is 

TCP/IP interface default address). To change the IP address, follow the instructions 

in the manual or in the online guide and technical help, specific for the Operating 

System you use.

Содержание TCP/IP-INT-TEX

Страница 1: ...TCP IP INT TEX User Manual Volume 1 Manufactured by Italy...

Страница 2: ...and bound in Italy No part of this manual may be reproduced memorized or transmitted in any form or by any means electronic or mechanic including photocopying recording or by any informa tion storage...

Страница 3: ...2 3 2 Treatment of electric burns 2 4 Unpacking 3 4 1 General Description 3 5 Installation and configuration procedure 5 5 1 Preparation 5 5 2 First Power On and Set Up 5 5 3 Management Software 6 6 E...

Страница 4: ...TCP IP INT TEX ii User Manual Rev 1 0 28 09 07 This page was intentionally left blank...

Страница 5: ...hile R V R Elettronica SpAattempts to provide accurate information it cannot accept responsibility or liability for any errors or inaccuracies in this manual including the products and the software de...

Страница 6: ...ediately Figure 4 placing your hands in the centre of the victim s chest Figure 5 Figure 3 Figure 4 Figure 5 One rescuer give 2 quick rescue breaths after each 15 compressions Two rescuers one rescue...

Страница 7: ...xchange data through the Internet such as ARP DHCP to assign IP addresses or like the conformity to RFC for TCP IP applications such as HTTP FTP server or e mail An important feature of the TCP IP INT...

Страница 8: ...hardware and firmware features and capabilities Please see the relevant sections for additional details 5 1 Preparation 5 1 1 Preliminary checks Unpack the TCP IP interface and immediately inspect it...

Страница 9: ...pment is ready for commissioning The WUI Web User Interface allows you to adjust modify or display the configuration variables and operation data Follow the procedure below to open the WUI 1 Open your...

Страница 10: ...d navigate to the showing page Device settings Allow the user to change the device settings Alarms Show the last ten active alarms Network settings Allow you to set up the network parameters General s...

Страница 11: ...automatic logout upon attempt to enter any of the sub menus the following page is displayed Attention User not logged in State 1 Repeat WUI access procedure to restore operating conditions with the sa...

Страница 12: ...ts 8 Analog outputs 1 Digital inputs 16 Digital outputs 16 Generic I O 13 Menu 4 Status Shows exciter connection state Model Shows exciter decimal ID number 10 is for TEX LCD series Harware Shows exci...

Страница 13: ...lation 0 2 KHz Forward Power 300 6 W Reflected Power 6 9 W Pa Voltage 50 5 V PA Current 9 A Temperature 3 6 C Power Out 100 Foldback Off State Ext R F Mute No Mute State Unlock Absent State Menu 5 Pow...

Страница 14: ...ation about the exciter connected to the TCP IP interface but also allows setting various parameters Following is a description of the items that allow modification of the parameter with respect to th...

Страница 15: ...ing in as administrator Within this menu you can display all alarms saved by the system any new event will automatically delete the older ones Using Reset item at bottom right of the menu you can dele...

Страница 16: ...e sub menus you need to have thorough technical knowledge of network management It is recommended to have changes performed by trained or qualified personnel 5 3 5 1 Ethernet menu Network settings Eth...

Страница 17: ...eway Shows and sets gateway address In simpler networks there is only one gateway that forwards to the internet network all the outbound traffic In more complicated networks where many subnets are ava...

Страница 18: ...3 5 3 POP3 menu Network settings Ethernet SMTP POP3 Server address POP3server User name Password Port 110 Update Menu 10 This page allows parameter configuration for receiving control messages throug...

Страница 19: ...ress the RVR logo the parameter setting will remain as previously set 5 3 6 1 Device menu General settings Run time DEVICE Device name TEX300LCD Node 1 Module 1 Echo timeout 1 Response timeout 1 Uart...

Страница 20: ...TX ALARM SECURITY Update Menu 12 This page allows configuration of the signal for alarms of the exciter connected to TCP IP interface Enable alarms Shows and sets alarm presence sampling time in secon...

Страница 21: ...WUI Enable login Enables 0 or disables 1 access to the menus by means of the login page User Name Manut Shows and sets the user name for administrator functions parameter reading and change enabling P...

Страница 22: ...at bottom right of this menu it is possible to restore software factory settings back up Commands RESET Reset the software of the interface and restart it Logout Logout the current user Menu 14 Reset...

Страница 23: ...ce to exciter 2 SERIAL 2 Not used Reserved for future implementations 6 2 Rear Panel Figure 6 2 1 NETWORK RJ45 connector for connection to LAN network ADSL router or PC 2 WEB SERVER MANAGER Green LED...

Страница 24: ...nual Rev 1 0 28 09 07 TCP IP INT TEX 6 3 Connector Pinouts 6 3 1 RS232 Type Female DB9 1 NC 2 SDA 3 SCL 4 NC 5 GND 6 NC 7 NC 8 NC 9 NC 6 3 2 POWER Type Female Microfit 1 V 5 30VDC power input approx 2...

Страница 25: ...t Network Included technology Integrated RFC conformity for applications where TCP IP is piloted by AT standard interface Dynamic DNS client and NTP TCP client and server for Telnet communication SMTP...

Страница 26: ...22 22 User Manual Rev 1 0 28 09 07 TCP IP INT TEX This page was intentionally left blank...

Отзывы: