The thresholds are expressed as percentage of full-scale value of the relevant
quantity.
The full scakle values for the HC5 are the following:
•
Forward Power
3000W
•
Reflect Power
300W
To change the values of the thresholds, execute the following procedure:
•
Select the line to modify (UP and DOWN buttons)
•
Push the ENTER button
•
Modify the value of the threshold (UP and DOWN buttons)
•
Push the ENTER button to confirm
The following figure shows an example of configuration for this menu.
In this example, the thresholds of the warnings are:
•
PwrGd 1
2400W
(80% X 3000W)
•
PwrGd2
1500W
(50% X 3000W)
•
RflWar
210W
(70% X 300W)
5.3.5
Alarms menu
This screen gives to the user information regarding the status of the protection
system included in the hybrid coupler.
It is constituted by a certain number of lines, each containing the name of a variable
controlled by the system and the kind of intervention that is undertaken by the
system in case the parameter surpasses its limit.
The latter can be of the kind: X - (Y), Wait, or Dis. (Disabled).
The aspect of this multi-line screen is the following (only two lines at a time are