5.3.7
Versions menu
This menu shows the hardware (H.V.) and software versions (S.V.) of the machine.
5.3.8
Protection sistem
The protection system implemented in hybrid coupler is based on two types of
reactions, the “Foldback” and the temporary disabling.
5.3.8.1
Foldback
The foldback circuit controls the level of a dc voltage that is available on the
dedicated BNC connector (F.BACK) on the rear of the HC2.
The foldback voltage remains approximately constant until one of the amounts
that are connected to the foldback doesn’t surpass its nominal value (full scale).
When this happens, the foldback voltage is rised proportionally to the amount the
threshold is surpassed, and a yellow LED is lit on the front panel, signalling the
intervention of the circuit. In figure 5-2, X represents one of the variables connected
to the foldback, X
0
is the full scale of the variable, V
FB
is the voltage present on the
BNC:
X
V
FB
X
0
Figure 5-1: Fold back voltage as a function variable “X”
In the HC2, the variables connected to the foldback are:
•
Forward power
•
Reflected power
•
Rejected power
•
Temperature
The foldback voltage can be used by the transmitter’s exciter to reduce accordingly
the driving power. For example, RVR Elettronica’s PTX-LCD is designed to use
an external foldback signal of this kind.
Содержание HC2 LCD
Страница 1: ...Manufactured by Italy HC2 LCD User Manual Volume 1...
Страница 4: ...HC2 ii User Manual Rev 1 1L 07 07 03 This page was intentionally left blank...
Страница 6: ...HC2 2 30 User Manual Rev 1 1L 07 07 03 This page was intentionally left blank...
Страница 22: ...HC2 18 30 User Manual Rev 1 1L 07 07 03 This page was intentionally left blank...
Страница 28: ...HC2 24 30 User Manual Rev 1 1L 07 07 03 This page was intentionally left blank...