PJ1002C-LCD
17
/ 24
User Manual
Rev. 1.0 - 30/10/15
will give 500 W, respectively, regardless of set power level. The Power
Good feature enables output power control and reporting. When output
power drops below set Power Good threshold, the equipment changes
the state of pin [9] of the DB25 “Remote” connector located on the rear
panel..
Pg2
Like
Pg1
, modifies a second Power Good threshold for forward
power. When output power drops below set Power Good threshold,
the equipment changes the state of pin [22] of the DB25 “Remote”
connector located on the rear panel..
Pg2
Like
Pg1
, modifies Power Good threshold for reflected power. When
output power drops below set Power Good threshold, the equipment
changes the state of pin [18] of the DB25 “Remote” connector located
on the rear panel..
Pg4
Like
Pg1
, modifies a second Power Good threshold for reflected
power.
5.4.2 Power Menu (Pwr)
This screen holds all readings related to machine output power:
Menu 5
Fwd
Forward power reading.
Rfl
Reflected power reading.
Inp
Input power reading.
Note that these are readings, rather than settings, and cannot be edited (note
the empty arrow). To change power setting, go to the
default menu
(menu 1) as
outlined earlier.
5.4.3 Power Amplifier (P.A) Menu
This screen is made up of four lines that can be scrolled using the buttons and
, shows the readings relating to final power stage: