Connections for PLASMA 50HF
Rear Machine connections
Fig 1
1. Air pressure regulating knob
This regulates the air pressure as displayed in gauge on front of machine. To adjust pressure pull knob upwards and
turn to adjust pressure, once correct pressure is obtained press down knob to secure.
2. Air pressure input
Screw supplied PCL fitting into regulator ensuring no air leaks You can also fit other connectors to suit your needs
3. 2
nd
Earth connection
This can be used to earth the machine to workbench if you are experiencing interference from the HF - Sometimes
required when using CNC automated machinery - Not normally used
4. Mains input cable
Fit required plug as per your electrical installation
5. POWER On/Off Switch
Turns machine on and off, the switch illuminates when machine turn on