background image

General information and warnings

Electronic automatic battery charger with microprocessor suitable for any battery type.
Fully automatic charging cycle with electronic setting protected against overload, short-circuit at clamps and reversed
polarity.
Never disconnect the battery while charging: this could cause sparks.
Never use the equipment in the rain, in areas used for washing or damp areas.
Before starting to charge, make sure the voltage of the equipment suits the voltage of the battery, that the charging current
suits the capacity of the battery and the selected charging curve(for lead-acid batteries or airtight gel batteries) is correct for
the type of battery to be charged. In addition, make sure the rated input voltage of the charger suits the available supply
voltage and the system is quipped with grounding.
If necessary, replace the fuse with another of the same type and value as indicated on the rating plate.
Use battery chargers only in well ventilated areas.
Pay attention to any remarks on the battery manufacturer.

For lead-acid batteries with liquid electrolyte:

Control the water level after each charging process.
Refill with distilled water only.
Caution! The gasses generated during charging are explosive. Do not smoke in the vicinity of the batteries. When working with
cables and electrical equipment, avoid open flames and sparks.
Attention: Use protective glasses and gloves during battery maintenance. Battery acid causes injuries. In case of contact with
battery acid, wash the affected parts with a lot of fresh water and consult a doctor if necessary.

Controls

1.

Three-digit d symbol (1), to view A = the charging current, U = the battery voltage, h = the charging time, C = the

charging ampere-hours [Ah], e = the energy used [KWh].

2.

Button for the selection of the display mode (2): A, U, h, C, E. After about 10 seconds the display returns to the visualization of

the charging current.

3.

Red control indicator (3): when it is on, the charging cycle has started.

4.

Yellow control indicator (4): when it is on, the final phase of the charging cycle as started.

5.

Green control indicator (5): when it is on, the charging cycle has finished.

Operation

Plug the cord into a socket.
Connect the battery, checking the polarity.
Now, the battery chargers display will show a sequence of details on the chargers internal programming: after the name “SPE”,
it will show the software release installed in the equipment, then in sequence, the following parameters: battery voltage,
charging current, charging curve number and, finally, the words “

GEL

” or “

ACD

” depending on the set up charging curve

being suitable for airtight gel batteries or lead acid batteries.

Make sure the type of batteries to be charged (gel or lead-acid

batteries) matches the displayed details (“GEL” or “ACD”, respectively). If it doesn't, contact our dealer

. Now a test is run on the

battery voltage to decide if the charging process should be started or not. If the battery is not connected to the battery
charger, the display will show the word “

BAT

”. The word will stay on, even if the test is failed (for instance, reversed polarities or

incorrect battery connection). If the test is passed, the display will show the battery voltage for approximately 5 seconds and
the battery will begin to be charged. The charging cycle progress will be shown by red (3), yellow (4) and green (5) LED
indicators. At the end of the charge, when the green indicator (5) is on, unplug the cord from the socket and operate the
machine.

Onboard battery charger display

PAGE 14

Problems

Solutions and checks

The battery charger does not sw itch on.

Check that the pug is connected to the supply mains and 
that the fuse is effcient

The charging cycle does not start and the message
"

bat

" is displayed.

Check the connection to the battery and the polarity.

The yellow  indicator (4) w ill not light up even 15 hours
from the starting of the charging cycle, and the display 

Check the battery for possible faulty components.

The message 

E01

 is displayed

This means that the maximum voltage admissible by the
battery has been exceeded. The charging is interupted.

If the battery charger is provided w ith a safety
thermostat and the message 

E02

 is displayed.

This means that the maximum temperature has been
exceeded. The charging is interrupted.

The message 

E03

 is displayed

This means that the maximum time for the charging 
phase has been exceeded. The charging is interrupted.

The message 

SCt

 is displayed

This means that the total safety timer has interrupted the 

The message 

Srt

 is displayed

This signals a possible internal chart circuit.

Содержание 200

Страница 1: ...Model 200 Operator Manual 200 Walkie Burnisher 2010 Edition 1 R P S Corporation Phone 1 800 450 9824 P O Box 241 Fax 1 866 632 6961 Racine Wisconsin 53401 00...

Страница 2: ......

Страница 3: ...PERATIONS section is to familiarize the operator with the operation and function of the machine The MAINTENANCE section contains preventative maintenance information to keep the machine and its compon...

Страница 4: ...Some of these exceptions are 1 Any Brooms Brushes Pads or Pad Drivers including Center Clip Retainers 2 Floor Seals Wipers Splash Curtains Squeegees or Gaskets 3 Filters Dust Collection Bags or Scree...

Страница 5: ...may find descriptions and features that are not on your particular model The information and specification included in this publication were in effect at the time of printing R P S Corporation reserv...

Страница 6: ...proper operating range to avoid tripping the circuit breaker SWEEPERS Demonstrate proper removal and replacement of main broom and side brooms Method for cleaning the dust filter empting out the debri...

Страница 7: ...STEM Pad Diameter Pad Motor Power Speed standard Pad Motor Power Speed optional Pad Engagement Pad Pressure Pad Pressure Settings BATTERY SYSTEM Battery AH Rating Battery Run Time Charger 110v 60 Hz a...

Страница 8: ...finishes May be used on a daily basis Ideally suited for top dressing highly polished floors Blended polyester and natural fibers For frequent burnishing on medium finishes Blended natural fiber pad...

Страница 9: ...his is intended for commercial use It is designed to be used on hard floors in an indoor environment with the recommended pads 1 DO NOT OPERATE UNIT Unless trained and authorized Unless operator manua...

Страница 10: ...Hazardous voltage Shock burns or electrocution can result Always disconnect the batteries before servicing machine WARNING Batteries emit hydrogen gases Explosion or fire can result Keep sparks and op...

Страница 11: ...Machine Controls and Features PAGE 7 24 25 26 27 28 29 30 2 10 9 7 6 13 11 12 17 16 14 15 8 19 18 1 4 5 3 2 20 21 22 23 30...

Страница 12: ...air into the burnishing motor 15 Burnisher motor cover Prevents dust from entering the burnisher motor prolonging motor life 16 Burnisher motor This motor drives the burnishing pad driver 17 Burnishe...

Страница 13: ...h 9 16 wrench see below 4 Turn on main power switch and check the battery condition meter to ensure correct installation Charge batteries if needed see battery charging PAGE 9 Machine Preperation Uncr...

Страница 14: ...in the center of the burnishing disk push up and screw in the pad clip Hand tighten only see right 6 Once the pad is in place tip the machine back down to the normal operating position 7 Run machine a...

Страница 15: ...se simply pull back on red togel switch located on the right hand side of central command box 7 To stop the machine let go of the green control button and the machine will stop automatically Operation...

Страница 16: ...h distilled water to just slightly cover the plates Do not over fill Batteries can overflow during charging Replace caps before charging 5 With the grey charger plug disconnected from the machine plug...

Страница 17: ...3 4 5 1 2 Onboard battery charger display PAGE 13...

Страница 18: ...a socket Connect the battery checking the polarity Now the battery chargers display will show a sequence of details on the chargers internal programming after the name SPE it will show the software re...

Страница 19: ...nance 1 Check pad condition Replace if necessary 2 Check battery charge 3 Clean dust control filters 4 Check hoses and verify there are no clogs 5 Check pads for wear and replace if needed 6 Charge un...

Страница 20: ...Hydrometer Reading Battery 4 Water condition Battery 5 Hydrometer Reading Battery 5 Water Condition Battery 6 Hydrometer Reading Battery 6 Water Condition Clean Battery Tops Check Battery Cable and Te...

Страница 21: ...age VISUALLY INSPECT IN SPEC REPAIR PROBLEM Vacuum Motor Brushes Vacuum Hoses Brush skirts Pad Motor Brushes Pad Driver Condition Drive Wheel Condition Front Caster Condition All Rollers COMMENTS Tech...

Страница 22: ...otor Faulty wiring Carbon brushes worn Faulty speed controller or wires Faulty potentiometer Loose wires Solution Contact local servicing dealer See charging batteries Replace battery Tighten loose ca...

Страница 23: ...ssive burnishing pad Pressure Worn drive tire Batteries run down Batteries still down Batteries low on water Batteries over cycled Solution Reconnect hose Reconnect hose Remove debris Contact local se...

Страница 24: ......

Страница 25: ......

Отзывы: