background image

METEOROLOGICAL INSTRUMENTS

INSTRUCTIONS

R.M. YOUNG COMPANY

   

2801 AERO PARK DRIVE,  TRAVERSE CITY,  MICHIGAN 49686, USA

TEL: (231) 946-3980      FAX: (231) 946-4772      WEB: www.youngusa.com 

P/N: 32500-90

 REV: U120717

ELECTRONIC COMPASS

W/ SERIAL INTERFACE

MODEL 32500

Содержание 32500

Страница 1: ...UMENTS INSTRUCTIONS R M YOUNG COMPANY 2801 AERO PARK DRIVE TRAVERSE CITY MICHIGAN 49686 USA TEL 231 946 3980 FAX 231 946 4772 WEB www youngusa com P N 32500 90 REV U120717 ELECTRONIC COMPASS W SERIAL INTERFACE MODEL 32500 ...

Страница 2: ... southern latitudes far from the equator since progressively more of the earth s magnetic flux becomes vertical By keeping the 32500 level at these latitudes the measurements will be free of the vertical flux influence and remain accurate If possible avoid installing the compass near magnetic devices or machinery Afterinstallation thecompassmustbecalibratedtocorrect for local magnetic conditions I...

Страница 3: ...lly noisy environments in applications where multiple units must be networked or in NMEA marine applications where RS 485 signals are required The full duplex RS 232 connection may transmit and receive serial data at the same time The RS 485 connection is half duplex meaning the unit cannot transmit and receive at the same time The 32500 internally manages the switch between modes Many application...

Страница 4: ...50 n INPUT TYPE 1 PULSE POT 2 VIN3 VIN4 Determines the type of wind speed and wind direction signal to use Type 1 is for standard WS pulse input wind speed and WD potentiometer wind direction input Type 2 is for VIN3 wind speed and VIN4 wind direction With Type 2 voltage inputs 0 to 5000mV 0 to 100 m s wind speed and 0 to 540 degrees wind direction These alternative inputs allow connection to devi...

Страница 5: ...Page 4 32500 90 U SERIAL OUTPUT FORMATS MODEL 32500 ...

Страница 6: ...Page 5 32500 90 U WIRING DIAGRAM MODEL 32500 JUMPER CONFIGURATIONS POWER ...

Страница 7: ...IAL WIRING CONNECTION MODEL 32500 Typical RS 232 connection to PC or other device 32500 jumpers set for RS 232 ASCII output Polled ASCII RS 485 half duplex serial connection to YOUNG 26800 Note jumper configuration on 32500 ...

Страница 8: ...Page 7 32500 90 U WIRING DIAGRAM Output to 06201 Wind Tracker ...

Страница 9: ...Page 8 32500 90 U WIRING DIAGRAM TYPICAL APPLICATION WIRING ...

Страница 10: ...Page 9 32500 90 U WIRING DIAGRAM NMEA2 TYPICAL WIRING WHEN USING NMEA2 FORMAT SENSORS MUST BE CONNECTED AS SHOWN FOR PROPER DATA REPORTING ...

Страница 11: ...Page 10 32500 90 U WIRING CONNECTION MODEL 32500 with 86000 86106 2D Sonic Anemometer ...

Отзывы: