User Manual ST-2300
Product Code.: 20 2300 556
Suttner GmbH, Hauptstraße 15-17, 33818 Leopoldshöhe
Tel.: +49(0)5208 - 91 46 - 0, Fax: +49(0)5208 - 91 46 - 15
www.rm-suttner.com, Email: [email protected]
6
Ver. 1.0
If the high pressure system has been used with hot water previously allow it to cool down to avoid the danger of scalding
or burning before commencing assembly and maintenance work.
Risk of injur
Risk of injur
Risk of injur
Risk of injury!
y!
y!
y!
Physical interference when the high pressure generator is running can lead to serious accidents.
▪ Switch the high pressure generator off before carrying out assembly work on the high pressure system.
▪ Secure the high pressure generator against being unintentionally switched on.
▪ Turn the water supply off.
▪ Ensure that system sections and lines to be opened are not under pressure.
Screwed connectors: Seal the screw connectors in accordance with your type of use with an appropriate sealant, e.g.
Omnifit 100 M SP. Tighten high pressure assembly screw connectors to a minimum of 25 Nm.
Shut off the high pressure hose from the high pressure generator to the spray gun input.
Assemble any intended accessory components to the output side.
After repair and maintenance work check proper functioning of safety equipment
Servicing
Servicing
Servicing
Servicing
Check annually that the spray gun is in a safe condition. Have any defects rectified immediately by a specialist
technician.
▪ Are all identification markings and labels legible?
▪ Does the spray gun shut off automatically?
▪ Does the safety lock function correctly?
After 1000 operating hours
After 1000 operating hours
After 1000 operating hours
After 1000 operating hours or one year or alternatively if using hot water (90°C plus) and chemicals 500 operating hours
or 6 months: Check valve components (seal seats, O-rings, thrust rings, ball, piston rod, pressure pad) for damage and if
necessary replace using a Suttner Repair Kit.
After 3000 operating hours
After 3000 operating hours
After 3000 operating hours
After 3000 operating hours or three years or alternatively if using hot water (90°C plus) and chemicals 1500 operating
hours or 18months: Replace valve components complete using a Suttner Repair Kit.
Disposal
Disposal
Disposal
Disposal