www.rm-suttner.com
page 7, Ver. 10.2020
Description
User manual easy
ST-167 / ST-168 bypass-injectors
Product code.: 200 167 ... / 200 168 ...
Table reading example for
scale setting
Flow volume:
15 l/min
Detergent or disinfectant concentration:
3 %
Calculated in accordance with the following formula:
(
3 % * 15 l/min
) / 100 % =
0,45 l/min
(dosage rate) =>
graph setting 2
(read from diagram)
Concentration
(%)
* Flow Volume
min
100
1
= Dosage
min
1
(
(
( )
)
)
The flow volume can be read from a
corresponding nozzle table
0,00
1
2
3
4
5
6
7
1
0
2
3
4
5
6
7
0,20
0,40
0,60
0,80
1,00
1,20
1,40
1,60
1,80
(10 l/min)
1,3 - 1,7
1,6 - 2,0
1,8 - 2,3
2,4 - 2,8
2,8 - 3,2
(15 l/min)
(20 l/min)
(30 l/min)
(40 l/min)
Medium: Water (p = approx. 998 kg/m
3
)
Note.: The graph only represents guide values
Scale setting
Dosage in l/min
Injector ST-161 with dosage nozzles "intake flow volume"