12
R/Evolution 2000 Series Troubleshooting Guide • May 2008
FRUs include:
■
Chassis-and-midplane. An enclosure’s 2U metal chassis and its midplane circuit
board comprise a single FRU. All other FRUs connect and interact through the
midplane.
■
Drive module. An enclosure can contain 12 SATA or SAS drive modules.
■
I/O module. A controller enclosure can contain one or two controller modules; a
drive enclosure can contain one or two expansion modules. Each type of I/O
module controls I/O between attached hosts and storage system disk drives.
■
Power-and-cooling modules.
The following sections describe each FRU in more detail.
Note –
Do not remove a FRU until the replacement is on-hand. Removing a FRU
without a replacement will disrupt the system airflow and cause an over-temperature
condition.
Enclosure Chassis and Midplane
An enclosure’s metal chassis is 2U in height. The front of the enclosure has two
rackmount flanges, called
ears
. The left ear has the enclosure ID display. The right
ear has enclosure status LEDs. The chassis also includes the midplane circuit board.
If the chassis or midplane is damaged they are replaced as a unit.
Midplane
The midplane circuit board is the common connection point for all system
electronics; all other FRUs plug into this board. Drive modules plug into the front of
the midplane. Power-and-cooling modules and I/O modules (controller modules or
drive modules) plug into the back of the midplane.
Содержание 2000 Series
Страница 1: ...2000 Series Troubleshooting Guide P N 83 00004287 12 Revision A May 2008 ...
Страница 18: ...18 R Evolution 2000 Series Troubleshooting Guide May 2008 ...
Страница 34: ...34 R Evolution 2000 Series Troubleshooting Guide May 2008 ...
Страница 64: ...64 R Evolution 2000 Series Troubleshooting Guide May 2008 ...
Страница 78: ...78 R Evolution 2000 Series Troubleshooting Guide May 2008 ...