background image

 

Section 3a

 – OPERATION

 

Key Features 

 

The Pool Pilot Digital display will show the 

SANITIZER OUTPUT LEVEL 

(in percent %) and whether the system is in 

BOOST

 or

 SUPER-BOOST Mode 

on the first line of the two line alphanumeric display.  The second line will display the 

current 

TIME

 in either 12 or 24-hr mode, the 

TEMPERATURE

 in either Fahrenheit or Celsius, whether the cell is powered 

or not, shown as ON or OFF and 

Polarity Direction

, shown as a “

.

” or blank.  Easy touch pads allow for adjusting and 

programming the unit.  A 

Check System

 visual alarm indicator works in conjunction with the display to advise of any 

problems.  All Menu, Select and Pump functions as well as any “Error messages” will be displayed on both lines of the 
alphanumeric display.   

 

 

 

 

 

 

 

POOL PILOT 

 

 

 

 

 

    

Digital

 

 
 

 

 

 

  

S a n i t i z e r

   

100%

 

 

 

 

 

12:00P   80F

 

   ON   

  

Check

 

 

 

 

 

 System 

  
 
 
 

 

 

 

Boost 

  Menu 

 Select 

  Pump  

 
 
The 

SANITIZING OUTPUT LEVEL

 is adjustable from 0% (OFF) to 100 % (MAX) by pressing the 

Up/Down

 Arrows to 

obtain the desired Sanitizer Output Level.  Little adjustment is needed once the initial setting is established.   

Note: The Pool Pilot Digital does not test for sanitizer levels nor automatically adjust to maintain a desired sanitizer 
level.  This is done by periodically testing the water and adjusting the output levels up or down, as needed.   

The Pool Pilot Digital is designed with an 

AUTOMATIC TEMPERATURE COMPENSATION feature

, which 

automatically adjusts the output level setting based upon changes in seasonal water temperatures only.  This unique feature 
conveniently compensates for warm (more sanitizer needed) or cold (less sanitizer needed) water conditions.  
 
The 

BOOST Button

 increases the sanitizer output level to 100% for up to 72 hours, regardless of the initial output level 

setting. The sanitizing agent is produced, continually; throughout the normal On/Off cycles of the pump and throughout all 
power line disturbances until the end of the cycle or when manually discontinued.  When Boost is activated with 

External 

Timer

 setting programmed, the time remaining for the boost cycle is held in memory and will start up in Boost mode until 

expired.    With

 Pump Program

 or 

2-Speed Pump

 setting programmed, the time clock will be over ridden, producing 

sanitizer until the end of the boost cycle.  The display will indicate the 

BOOST

 

Mode 

on the second line when the boost 

Button is pressed once.  Once activated, the system will produce the sanitizing agent for 24 hours.  The sanitizing agent can be 
produced for 72 hours by pressing and holding down the Boost Button for 5-seconds from the Boost-Off position.  This is 
called the 

SUPERBOOST

 

Mode

.  The display will indicate that the system has successfully entered the Super Boost mode.  

To discontinue operation of Boost mode or Super Boost mode, pressed the Boost Button once more.  The pool/spa pump must 
be turned on during the whole boost cycle.  Do not let the pump run on a timer during that period. 

 

The 

Menu

 and 

Select Buttons

 allows you to view the TEST mode, program the functions and time clocks.  See the following 

pages for description of the menu tree. 

 

* The 

PUMP Button

 allows you to over ride the pump timer to temporarily turn the pump on or off (depending on its status of 

operation), or to manually turn the pump off, indicated by the display “OFF FOR MAINTENANCE”.  In “OFF FOR 
MAINTENANCE” mode, the pump is prevented from restarting by the time clock and is only reactivated only by manually 
programming it to turn the pump back on.   Not applicable with “EXTERNAL TIMER” selection.

 

 

The 

CHECK SYSTEM

 light will flash if there is a problem with the system.  The nature of the problem will be indicated by 

the display through various error messages.  See the Troubleshooting section, page 14, for repair solution.  

 

FREEZE PROTECTION

this protective feature allows the pump, when programmed for One-Speed Pump, to override the 

program cycle and run continually (30-minute minimum) when the water temperature falls below 4.4°C (40

°

F).  This prevents 

any damage to the PVC due to water expanding as it freezes.  

Содержание CRISTAL MAGIC Pool Pilot Digital 36

Страница 1: ...cteria And Algae In Swimming Pool Waters For Indoor or Outdoor Use RETAIN MANUAL FOR FUTURE REFERENCE CRISTAL MAGIC IMPORTANT READ THE LABEL AND THIS MANUAL BEFORE INSTALLING OPERATING Notice to User...

Страница 2: ...___________ Control Unit Control Unit Model Number DIG36______________ Serial Number ____________________________ Cell Cell Model RC 5 Serial Number ____________________________ Customer Assistance HO...

Страница 3: ...ater chemistry in accordance with manufacturer s instructions 6 DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times Children...

Страница 4: ...Connections Remote ORP Connections 2b Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Display Panel 7 9 3b Pool Water Preparation 10 Salt...

Страница 5: ...ing See page 10 for salt requirements the tri sensor assembly holes to tighten the screws RATINGS Input Power 115 VAC 3 0 AC amps MaximumOutput Equivalent to 0 58 kg 1 28 lbs of free available chlorin...

Страница 6: ...AD SIDE of your time clock electronic controller switch or relay to work in conjunction with your circulation pump For control of your main circulation pump single or two speed through the Pool Pilot...

Страница 7: ...erify that the flow switch is working as designed which is to halt power from being sent to the cell in the presence of insufficient flow A defective Flow Switch could cause serious personal and or eq...

Страница 8: ...r when manually discontinued When Boost is activated with External Timer setting programmed the time remaining for the boost cycle is held in memory and will start up in Boost mode until expired With...

Страница 9: ...ub menu After completing a step it displays the next step 2 1 English Metric displays volume in gallons or cubic meters salt additions in lbs or kg Back Main Menu 2 0 2 2 Temperature Units displays th...

Страница 10: ...3 7 Calibrate Salt allows you to calibrate the salt display Contact the factory for calibration solution 3 8 Replace Cell Only used when replacing cells May be used to zero the amp hour counter Consul...

Страница 11: ...e NaCl NOTE Do not use Rock Salt due to its high levels of impurities TEST YOUR WATER FOR SALT LEVEL FIRST with the provided salt test strips and then use the chart below to determine the amount of sa...

Страница 12: ...ls Maintain and balance only as needed CYANURIC ACID STABILIZER CONDITIONER This chemical goes by either trade name and allows your chlorine residual to last longer by protecting it from the UV degrad...

Страница 13: ...s and Access is gained to you do not need to wire harness Control Circuit lift off metal cover electrical connections remove these board removes with cover and fuses Fuse Location and Ratings F1 Main...

Страница 14: ...treated with a mixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution in a container high enough to cover the Cell blades You may also use non fuming pre mixed cell cleaner per...

Страница 15: ...ordered separately Red Cap Plug for RC 5 cell cord 19050 12 ft 3 6m Cell Cord 952 1 Union O Ring 19013 Cell RC 5 Nut Half only 2 pcs for 2 in 50 mm S x S Union Thread Half Only for 2 in 50 mm S x S Un...

Страница 16: ...corrosion 4 Premature Cell Failure Requires Replacement Cell A Abnormally high Cell usage due to an insufficient A Check the stabilizer level and adjust to recommended levels Stabilizer Cyanuric acid...

Страница 17: ...st Control Products Act to use a control product under unsafe conditions For swimming pools a minimum of 1 ppm of free available chlorine or bromine must be maintained For spas a minimum of 3 ppm of f...

Страница 18: ...DUCTS ACT This cell must only be used on this model of chlorine generating device Read the Label and the Installation and Operation Manual of the chlorine generating device RBF CRISTAL MAGIC Model DIG...

Страница 19: ...ormation This service and this information do not replace the official hard copy label The PMRA does not provide any guarantee or assurance that the information obtained through this service is accura...

Отзывы: