15
16
Infrared setting
7
.
Infrared led setting
7.1 IR SENSITIVITY:
infrared automatic open sensitivity settings, range 0~100, the user can
according to the environmental illumination status modulates infrared
automatic open
7.2 MANUAL DELAY:
infrared light manual opening, closing time, if time is 0,Do not
automatically close infrared lamp
7.3 IR ON/OFF:
IR control mode, can be divided into a, AUTO, MANUAL, TIME
three models,In TIME model, according to the user set time to switch
IR; in MANUAL mode,Call the 62 preset command to open the
infrared light, open the63 preset closed lamp
7.4 IR LUMINANCE:
infrared brightness control method in infrared light,open effect after,
Divided into: AUTO, GROUP, MANUAL, three states AUTO mode,
infrared automatic brightness matching lens distance, according to the
cameralens changes,Infrared high beam and dipped beam headlights
will automatically adjust the brightness, reach the intensity of
illumination and brightness automatic matching,And can improve the
infrared lamp life.
GROUP mode
:
packet mode,in a packet mode,infrared high beam and
dipped beam headlights will match According to the lens distance packet
opened at the same time.
MANUAL mode: the manual control mode, infrared brightness from
the lens parameters influence,The user can set the high beam and dipped
beam brightness, range 0~100
MAIN MENU
SYSTEM
CAMERA
FUNCTION
INFRARED LED
ALARMS SETUP
EXIT
INFRARED LED
MANUAL DELAY
IR ON/OFF
LUMINANCE
BACK
EXIT
SENSITIVITY
IR ON/OFF
ON TIME N/A
OFF TIME N/A
BACK
EXIT
IR ON/OFF AUTO
LUMINANCE
TELE LED N/A
WIDE LED N/A
BACK
EXIT
LUMINANCE
AUTO
Alarm
setting
MAIN MENU
SYSTEM
CAMERA
FUNCTION
INFRARED LED
ALARMS SETUP
EXIT
ALARM SETUP
INPUT CHANNEL 1
ALARM ACTION NONE
ACTIVATE AUX AUX1
ALARM CONTACT NO
RESET DELAY 30
ARM SETTING
EXIT
8.
Alarm function
Speed dome may connect with 4 alarm input, 1 alarm output, and support
alarm linkage. The external alarm message sends to the dome, then the dome
sends to alarm point shoot (to call preset, auto scan, auto cruise and auto pattern)
, and choose that to run alarm output or not.
The system enters into the main menu by calling 95 preset orby calling 9
preset twice within 3 seconds. click each menu according to the left picture,
then enter menu alarm, choices as follow:
as current alarm input, to run the action. Choices
for choosing as follow. NONE---none action/SCAN/PAT X---run a
pattern tour/TOUR---run tour/PRESET---call preset, when the dome
number is set as 1, to call preset 1; when the dome number is set as 2,
to call preset2.
as current alarm input, to run alarm output or not.
NONE---none alarm output/AUX 1---the first alarm output/AUX 2---
the sec-retaryond alarm output/BOTH--- two alarms output
set state of the relay. N/C---often close the state,
N/O---often hold the state. If setting as often closing the state, the relay
is in closing the state when there is no alarm to output;when there is
alarm to output, the relay is in holding the state.
set alarm reset and delay the time (1-225s)
,
how
long to relieve and run
RESUME
after the dome receives alarm
message.
2
operate the joystick up and down and move the curs-or to
DAY
,
press
OPEN
to choose it , operate the joystick up and
down to set day of the week. To set the Alarm state and Alarm date is
based on it.
ARM STATE
: alarm on /Alarm off
(Alarm setting is effective only under alarm on.)
ARM TIME : user can set the alarm time.
DISARM TIME
: user can set the alarm turnoff time.
1
、
●【
ALARM ACTION
】
●
【
ACTIVATE AUX
】
●【
ALARM CONTACT
】
● 【
RESET DELAY
】
【
】
【
ARM SETTING
】
●
【
】
【
】
【
】
【
】
【
】
ARM SETTING
DAY MON
ARM STATE ON
ARM TIME 00:00
DISARM TIME 00:00
EXIT