background image

33

4.3.4 Alarm input

When the system gets an external alarm signal, the alarm function is turned on. 

Picture 4.11 Alarm input

Set method: refer to chapter 4.3.1. Motion detect

Note:"Advanced" button is the same as rightclick.

4.3.5 Alarm output

 

Refer to chapter 3.5.4.

4.3.4 Abnormal

Analysing  and  inspecting  current  software  and  hardware  of  the  device:  When 
some abnormal events happen, the device will make a relative answer such as 
show message and buzzer. 

Picture 4.12 Abnormal

(

Event Type

) Selecting the abnormity you want to inspect

(

Enable

) Select it to make sure the abnormal function works

(

Show message

) Automatically an alarm cue dialog box comes up on the main 

screen
(

Buzzer

) The device will have a “di di” noise when the alarm is sounding

Содержание ATLANTIS 1U

Страница 1: ...1 U 4 8 16 Channel DVR User s Manual...

Страница 2: ...FOR LESS ALL OUR PRODUCTS CARRY LOGOS ENHANCE YOUR DVR WITH OUR WIDE RANGE OF CAMERAS OUR PRODUCTS ARE FULLY TESTED TO WORK TOGETHER EYEBALL DOMES VANDAL DOMES P400 CAMERAS PTZ CAMERAS INTERNAL DOMES...

Страница 3: ...12 2 6 3 Alarm output port relay perameters 13 2 7 Speed dome connections 13 3 Basic operation 14 3 1 Turn on 14 3 2 Turn off 14 3 3 System Login 14 3 4 Preview 15 3 5 Desktop shortcut menu 15 3 5 1...

Страница 4: ...2 Account 45 4 5 3 Online user 47 4 5 4 TV adjustment 47 4 5 5 Auto maintain 47 4 5 6 Restore 47 4 5 7 Upgrade 48 4 5 8 Device Info 48 4 6 Info 48 4 6 1 HDD info 48 4 6 2 BPS 49 4 6 3 Log 49 4 6 4 Ver...

Страница 5: ...e DVR Please brush printed circuit boards connectors fans machine box and so on regularly Before cleaning however please switch off the power supply and unplug it from the mains Do not attempt to disa...

Страница 6: ...nt panel power wire and the connection between the fan power and the main board Front and rear panel l The key functions on the front panel and the interface specification for the real panel are in th...

Страница 7: ...icator light 3 Alarm indicator light 4 HDD indicator light 5 Record indicator light 6 Network indicator light 7 Status indicator lighter 8 Running indicator lights 9 Back to main course 10 PTZ control...

Страница 8: ...to the previous menu or the function menu to cancel the operation In the Video playback state to return to the real time monitoring 12 Power switch Press this key to perform boot and shutdown operati...

Страница 9: ...e interface for a 4 channel rear panel of a DVR See Appendix 3 on page 57 for more details for specific models 1 Video input 4 USB 7 VGA 2 Video output 5 Network 8 Power 3 Audio output 6 Audio input 9...

Страница 10: ...hould be away from all electro magnetic Interference and other signal line equipment High voltage current should be especially avoided Insure the connection is stable The signal and shield lines shoul...

Страница 11: ...s the grounding voltage signal C When the alarm is connected with two DVRs or connected with DVR and other equipments it should be isolated by relay 2 Alarm output Alarm output can not be connected wi...

Страница 12: ...rm input Alarm input type unlimited The earth and the com port of the alarm sensor are parallel The alarm sensor has an external power supply The earth of the alarm and the DVR should be shared The NC...

Страница 13: ...1000VAC 1minute Inhomo polarity interface 1000VAC 1 minute Interface and winding 1000VAC 1 minute Surge voltage Homo polarity 1500VAC 10 160us Turn on time 3ms max Turn off time 3ms max longevity Mec...

Страница 14: ...If the DVR is shut down abnormally it can automatically backup video and resume the previous working status after a power failure 2 Replace the hard disk Before replacing the hard disk the power suppl...

Страница 15: ...n 3 4 Preview You can right click mouse to choose the switch between the windows The system date time and channel name are shown in each viewing window The surveillance video and the alarm status are...

Страница 16: ...16 Picture 3 2 Shortcut Menu 3 5 1 Main menu When you login the system main menu is shown as below Picture 3 3 Main Menu...

Страница 17: ...Listed files 2 File information 3 File searching 4 File backup 5 Operation hint 6 Playback control Listed files Look up the listed files that accord with the searching criteria File information Look u...

Страница 18: ...Clear the file information Add Show the file information satisfying the set file attributes Start Pause Click the play button to start the backup and click the pause button to stop the backup Cancel...

Страница 19: ...gle window full screen playback mode you can drag your mouse in the screen to select a section and then left click your mouse to view this in local zoom You can right click your mouse to exit 3 5 3 Re...

Страница 20: ...he channel in any state Stop Click the stop button and the according channel stops alarming no matter the channel in any state 3 5 5 PTZ control The PTZ Operation interface is as followed The function...

Страница 21: ...preset points and the PTZ will automatically turn to the setting position 1 Preset option To set a location for the preset the procedure is as follows Step 1 In Picture 3 10 use the direction button...

Страница 22: ...reset The number of presets in the tour will show in the Preset box Step 3 repeat steps 1 and 2 until you have set out all the preset designated cruise positions Remove Preset Please input the preset...

Страница 23: ...utton to enter the PTZ control menu as shown in Picture 3 12 Please input the number of the scan in the value blank then click the AutoScan button the PTZ will begin to work on the scan line Click the...

Страница 24: ...ton to go to Picture 3 16 setting the auxiliary function Set the auxiliary number corresponding to auxiliary switch on the decoder Picture 3 16 Auxiliary Function Control Intuitive Auxiliary Operation...

Страница 25: ...shortcut menu or enter main menu Picture 3 20 Logout Reboot the system Logout Quit the menu Use to switch user Shut down Quit the system Turns off the power supply When you press the shut down button...

Страница 26: ...ation Set main assistant coding parameter code mode resolving ability frame rate code stream control image quality type code stream value frame between value video audio enable Network configuration S...

Страница 27: ...the channel Choose the all option to set every channel to the same Redundancy Choose the redundancy function option to implement the file double backup function Double backup is writing the video file...

Страница 28: ...napshot storage pls setup Snap at Main Menu Advanced Snapshot pls refer to chapter 4 5 1 HDD Manage Picture 4 2 Channel Select the related channel to set click all to set all channels Presnap Setup pr...

Страница 29: ...d disk or universal disk Erase Choose the file to delete and click erasure to delete the file Stop Stop the backup Backup Click backup button and the dialog box pops up You can choose the backup file...

Страница 30: ...that the motion detect function is on Sensitivity Choose in the six options according to the sensitivity Region Click setup and enter the set area The area is divided into PAL 8x8 Green block means th...

Страница 31: ...e selected channel is a single window alternate patrol preview The interval is set in the MainMenu System Tour Snapshot Choose record channels when the alarm activates the system triggers the related...

Страница 32: ...are turned on Picture 4 9 Video Blind Set method refer to chapter 4 3 1 Motion detect Note Advanced button is the same as right click 4 3 3 Video Loss When the equipment can not obtain the channel vid...

Страница 33: ...Abnormal Analysing and inspecting current software and hardware of the device When some abnormal events happen the device will make a relative answer such as show message and buzzer Picture 4 12 Abno...

Страница 34: ...ussian Thai T Chinese S Chinese Turkish Brazilian Bulgarian Farsi French German Hebrew Hungarian Polish Romanian Spanish Swedish Vietnamese HDD full Choose stop record Stop recording when the hard dis...

Страница 35: ...e P 1 frame s 25 frame s N 1 frame s 30 frame s Bit Rate Type You can choose limited code stream or variable code stream When you choose the variable code stream there are six image quality options Bi...

Страница 36: ...ess must be set and reboot then it works TCP port Default 34567 HTTP port Default 80 HS Download Transfer Policy There are three strategies self adaption image quality precedence and fluency precedenc...

Страница 37: ...address to visit the DVR through user port NTP setup Picture 4 20 NTP The NTP server must be installed in the PC Host computer IP Input the IP address installed NTP server Port Default 123 You can se...

Страница 38: ...e user password Sender Set the senders email address Receiver Send the email to the appointed receiver s when the alarm is turned on You can set up to three receivers Title You can set this as you wis...

Страница 39: ...k setup Picture 4 23 DDNS setup FTP setup FTP is available only when an alarm happens or an alarm activates a record and takes a snapshot it will then upload the related records and snapshot pictures...

Страница 40: ...ice Picture 4 25 Wireless Config Enable Choose Enable to make all settings available Type Dial type default AUTO Wireless AP 3G access point Dial Number 3G Dial Number User Name User name of 3G Passwo...

Страница 41: ...HTTP Route will automatically distribute HTTP port for the device when IE viewing it need this port eg 60 12 9 26 66 TCP Router will automatically distribute TCP port for the device when monitoring v...

Страница 42: ...e surveillance window Channel Title means the selected state This displays the system channel number in the surveillance window Record Status means the selected state This displays the system recordin...

Страница 43: ...aud rate length You can control the PTZ and vidicon Default 115200 Data bits Include 5 8 options Default 8 Stop bits Include 2 options Default 1 Parity Include odd check even check sign check blank ch...

Страница 44: ...age Configure and manage the hard disk The menu displays current hard disk information hard disk number input port type status and overall capability The operation include setup the write read disk re...

Страница 45: ...setup includes user admin You can set the team as you wish The user can appoint the purview in the group 3 User management includes group user The group and user name can not be the same Each user onl...

Страница 46: ...subclass of that team We recommend that the common user s authority is lower than the advanced user Picture 4 35 add user Add Group To add a new user team and set their authority There are 36 differen...

Страница 47: ...r is locked until next boot strap Picture 4 38 Online User 4 5 4 TV adjust Refer to chapter 3 5 7 4 5 5 Auto Maintain The user can set the auto reboot time and auto file deleting time limit Picture 4...

Страница 48: ...eeds upgraded 4 5 8 Device Info Provide device interface info like audio in alarm in out to be conveniently used for user Picture 4 42 Device Info 4 6 Info 4 6 1 HDD info Display the hard disk state h...

Страница 49: ...PS Displays the code stream Kb S and hard disk capability MB H in real time It displays as a wave sketch map Picture 4 44 BPS 4 6 3 LOG Look up the system log according to the set mode Log information...

Страница 50: ...50 4 6 4 Version Display the basic information such as hardware information software edition issue data and so on Picture 4 46 Version 4 7 Shut down system Refer to chapter 3 5 8...

Страница 51: ...the hard disk lines are broken 3 The power of the switch power supply is low 4 Frontal video signal is not stable 5 Bad heat radiator or too much dust or bad running circumstance for the DVR 6 The ha...

Страница 52: ...vered 5 The recording is not on 7 The local video is not clear Possible reasons are as followed 1 The image quality is too bad 2 The reading program is wrong Reboot up the DVR 3 The data line of the h...

Страница 53: ...is not correct 3 The sensitivity is too low 4 Limited by some hardware edition 13 I can not login via web or CMS Possible reasons are as followed 1 The system is windows 98 or win me We recommend upd...

Страница 54: ...r supply is not large enough Please give each transformer individual power supply 4 The distance is too far 18 Alarm can not be recessional Possible reasons are as followed 1 The setting of the alarm...

Страница 55: ...vice We will offer the service according the machine type and the program edition 5 2 Maintenance 1 Please brush the printed circuit boards connectors fans machine box and associated parts regularly 2...

Страница 56: ...an example The mouse in USB connection is supported Operation Function Double left click Double click one item in the file list to playback the video Double click the playback video to zoom in or out...

Страница 57: ...ions Recording speed 100 120fps D1 200 240fps CIF 50 60fps D1 400 480fps CIF 100 120fps D1 Motion detect 64 8 8 detection areas multiple sensitivity Audio Audio compression G711A Bidrectional Talk Sup...

Страница 58: ...ower supply 12V 2A external power supply Power consumption 15W without hard disk Working temperature 0 C 55 C Working humidity 10 90 Air pressure 86kpa 106kpa Size 350 290 45MM Weight 3 5kg without ha...

Отзывы: