Quuppa Q17 Скачать руководство пользователя страница 17

 

 

 

 

17/19 

Quuppa Q17 Installation Guide and Safety Information 

 

Quuppa Oy, Keilaranta 1, 02150 Espoo, Finland 

© 2018 Quuppa Oy 

 

Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type 
and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential 
radio interference to other users, the antenna type and its gain should be chosen so that the equivalent 
isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. 
 
Radiation Exposure Statement: 
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. 
This equipment should be installed and operated with greater than 20cm between the radiator & your 
body. 
 

Le présent appareil est conforme aux CNR d’ ISED applicables aux appareils radio exempts de licence. 
L’exploitation est autorisée aux deux condit

ions suivantes :  

1.

 

le dispositif ne doit pas produire de brouillage préjudiciable, et  

2.

 

ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer 
un fonctionnement indésirable. 

 
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec 
une  antenne  d'un  type  et  d'un  gain  maximal  (ou  inférieur)  approuvé  pour  l'émetteur  par  Industrie 
Canada.  Dans  le  but  de  réduire  les  risques  de  brouillage  radio  électrique  à  l'intention  des  autres 
utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée 
équivalente  (p.i.r.e.)  ne  dépasse  pas  l'intensité  nécessaire  à  l'établissement  d'une  communication 
satisfaisante.  
 

Déclaration d’exposition aux radia

tions: 

Cet  équipement  est  conforme  aux  limites  d’exposition  aux  rayonnements  ISED

  établies  pour  un 

environnement  non  contrôlé.  Cet  équipement  doit  être  installé  et  utilisé  à  plus  de  20  cm  entre  le 
radiateur et votre corps. 
 
 

8.2.

 

FCC Statement 

 
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:  

1.

 

This device may not cause harmful interference; and 

2.

 

This  device  must  accept  any  interference  received,  including  interference  that  may  cause 
undesired operation. 

 
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant 
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference in a residential installation. This equipment generates uses and can radiate radio frequency 
energy and, if not installed and used in accordance with the instructions, may cause harmful interference 
to radio communications. However, there is no guarantee that interference will not occur in a particular 
installation. If this equipment does cause harmful interference to radio or television reception, which 
can be determined by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures: 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 
connected. 

Содержание Q17

Страница 1: ...Quuppa Q17 Quuppa Locator Installation Guide and Safety Information v 1 1 11 1 2019...

Страница 2: ...ion Guide and Safety Information Quuppa Oy Keilaranta 1 02150 Espoo Finland 2018 Quuppa Oy Revision History Version number Changes Date Person 1 0 First version 18 Dec 2018 MV SE 1 1 Added FCC and IC...

Страница 3: ...ain unit to the mounting bracket 11 5 2 Connect to power supply 12 Option 1 Use Power over Ethernet PoE 12 Option 2 Use separate 5V DC Micro USB 12 5 3 Connect to network 12 5 4 Reset to factory setti...

Страница 4: ...4 19 Quuppa Q17 Installation Guide and Safety Information Quuppa Oy Keilaranta 1 02150 Espoo Finland 2018 Quuppa Oy...

Страница 5: ...ot connect incompatible products When connecting to any other device read its user guide for detailed safety instructions Do not connect incompatible products 2 Introduction Quuppa Q17 Quuppa Locator...

Страница 6: ...ion Guide and Safety Information Quuppa Oy Keilaranta 1 02150 Espoo Finland 2018 Quuppa Oy 3 Parts The Quuppa Q17 contains the following parts 1 Quuppa Q17 main unit 2 Quuppa Q17 mounting bracket 3 Qu...

Страница 7: ...Guide and Safety Information Quuppa Oy Keilaranta 1 02150 Espoo Finland 2018 Quuppa Oy 3 1 Quuppa Q17 main unit 1 Indicator light 2 Bracket mounting channel 3 Type label 4 Ethernet connector 5 Micro...

Страница 8: ...Quuppa Oy 3 2 Quuppa Q17 mounting bracket 1 Orientation indicator and orientation guideline 2 Installation guide 3 VESA standard 75mm x 50mm and 50mm x 50mm 4 Cable passage 5 Locking mechanism 3 3 Qu...

Страница 9: ...llation Consult Quuppa in case you are uncertain about installation in a specific indoor environment Quuppa Q17 is designed to operate either by using a standard PoE Power over Ethernet compatible net...

Страница 10: ...ws Use at least 4 screws to ensure a stable installation The recommended pattern is either VESA standard 75mm x 50mm or 50mm x 50mm which are both indicated on the mounting bracket Ethernet cable can...

Страница 11: ...le if that is used 2 You may use the connector cover to protect the connector area from dust and dirt 3 Align Quuppa Q17 main unit with the bracket by ensuring the installation guide in the mounting b...

Страница 12: ...r light turns constantly on until the Quuppa Q17 is connected to the Quuppa Positioning Engine 5 3 Connect to network Connect Quuppa Q17 to a network with Ethernet CAT5 UTP cable using the RJ 45 Ether...

Страница 13: ...and Safety Information Quuppa Oy Keilaranta 1 02150 Espoo Finland 2018 Quuppa Oy 6 Product Information 6 1 Q17 Mechanical Details Q17 dimensions Picture 5 Dimensions side view Picture 6 Dimensions to...

Страница 14: ...tection class No Operating temp range 0 C 60 C Storage temp range 10 C 70 C Carrier frequencies 2401 2402 2480 2481 MHz Positioning radio 2402 2404 2478 2480 MHz Communication radio Power supply 48 V...

Страница 15: ...rong detergents to clean the device Only use soft clean a dry cloth to clean the surface of the device Do not paint the device Keep the device out of reach of small children 7 Recycling and disposal A...

Страница 16: ...a time Carrier frequencies 2402 2404 2478 2480 MHz Modulation GFSK Max Output Power 2 5 mW Antenna Folded dipole antenna with 0 dBi gain The enclosed device complies with Part 15 of the FCC Rules Ope...

Страница 17: ...te que la puissance isotrope rayonn e quivalente p i r e ne d passe pas l intensit n cessaire l tablissement d une communication satisfaisante D claration d exposition aux radiations Cet quipement est...

Страница 18: ...an for help WARNING Changes or modifications not expressly approved by Quuppa could void the user s authority to operate the equipment Radiation Exposure Statement This equipment complies with FCC rad...

Страница 19: ...ake changes and improvements to any of the products described in this document without prior notice TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW UNDER NO CIRCUMSTANCES SHALL QUUPPA OR ANY OF ITS...

Отзывы: