background image

W A RN I N G  

- Turn off the power!

REM EM BER 

- Turn off the power!

DO NOT fasten the blades to the fan
until it is assembled and hanging from
the ceiling. To do so now will likely
bend the blade arms and almost cer-
tainly cause wobble.

1.

If not already affixed to the hanger

bracket, place the rectangular rubber 
isolators between the hanger bracket and
outlet box. Secure the hanger bracket to
the outlet box using the 2 long steel
screws supplied with the fan.

2.

Remove the set pin and safety lock

clip from the downrod/ball assembly.
(Fig. 5) Slide the downrod through the
canopy, hanging bar hooks (use only if
12" downrod is used) and yoke cover.
Feed the wires from the fan motor
through the downrod assembly.

3.

(Fig. 6) Attach the downrod 

assembly to the motor by sliding the
downrod into the yoke on top of the
motor assembly. Slide the set pin through
the hole in the yoke, downrod and wash-
er and secure it with the safety lock clip.
Tighten the set screws on yoke. Cover
with yoke cover. 

4.

Lift the fan motor without the blades

and place into the hanger bracket, rotat-
ing the ball until the groove engages the
tab on the hanger bracket. This locks the
ball mount and fan motor, preventing fan
rotation during operation.

Use the wires nuts supplied with your
fan when making connections. Secure
the connectors with electrical tape and
make sure there are no loose connections
or wire strands.

• Connect the other BLACK wire from

the transmitter to the remaining
BLACK wire from the wall (A/C sup-
ply source).

5.

If your junction box has a ground

wire (Green or bare Copper), connect the
transmitter ground wire to it. Otherwise,
connect the transmitter ground wire
directly to one of the screws from the
outlet box.

6.

Before mounting the wall transmit-

ter, be sure to check the DIP switch set-
ting to be sure they match the setting
selected on the receiver unit.

7.

Carefully tuck the connected wires

inside the junction box. Secure the wall
transmitter with the two screws provided.
Attach the faceplate over the transmitter

1.

Make wire connections from the fan

to the wall control receiver unit. For this
step use the bundle of 4 wires on the
canopy receiver. (Fig. 7).

• Connect the BLACK fan wire to the

BLACK receiver wire.

• Connect the BLUE fan wire to the

BLUE receiver wire.

• Connect the WHITE fan wire to the

WHITE receiver wire.

• Connect the ORANGE fan wire to the

ORANGE receiver wire.

2.

Connect the wiring from the ceiling

to the canopy receiver.  (Use the 2 wire
bundle on the receiver.) 

• Connect the BLACK building supply

wire to the BLACK receiver wire.

• Connect the WHITE building supply

wire to the WHITE receiver wire.

• Connect the COPPER building

ground wire to the GREEN fan
ground wire.

3.

Before securing the ceiling canopy,

select the switch code setting with the
DIP switches on the canopy receiver.
Note that at least one of the 4 DIP
switches must be in the “on” position.
Also note the DIP switches on the wall
transmitter unit must be set the same as
on the receiver unit.

4.

Connect the wiring from the wall

switch receptacle to wall transmitter unit.  

• Remove the existing wall plate and

switch from the wall junction box.

• Connect one BLACK wire from the

wall to one Black wire (labeled “ TO
FAN ”) from the wall transmitter.

with the two White screws provided.

Note:

This wall control and receiver unit

has 16 different code combinations. Your
fan will not operate if the switch settings
do not match. If you have another remote
operated fan in your home, make sure
the DIP switch setting you have selected
will not interfere with your existing fan.
If it does, simply change the DIP switch
settings in both the canopy receiver unit
and wall transmitter unit.

B

L

K

W

H

G

ro

u

n

d

B

L

U

B

L

K

W

H

O

R

A

N

G

E

G

R

N

B

L

U

B

L

K

W

H

O

R

N

G

B

L

K

W

H

BLK

BLK

BLK

BLK

GRN

Fig. 7

Use ONLY wall controls approved
by Quorum. Use of unapproved wall
controls will cause unacceptable
humming noise, and voids the fan
warranty.

Fig. 5

Downrod

Canopy

Hanging Bar Hooks

Yoke Cover

Fig. 6

Downrod 
Assembly

Washer

Yoke
Set Screws

Yoke

Safety
Lock Clip

Set Pin

W A RN I N G  

- To reduce the risk of shock, fire or injury, mount the fan ONLY to

an outlet marked “Acceptable for Fan Support”.

1.

Disconnect the power by removing

fuses or turning off circuit breakers.

2.

If there is an existing outlet box,

ensure it is clearly marked “Suitable For
Fan Support”. If it is not so marked, it
must be replaced with an approved one.

3.

Secure the outlet box (or make sure

the existing box is secured) directly to
the building structure. Use appropriate
fasteners and building materials.

4.

Figures 1, 2 and 3 are examples of

different ways to mount the outlet box in
different situations. A longer downrod
may be required in sloped ceiling situa-
tions to maintain proper blade clearance.

5.

To hang the fan in locations where

no ceiling joist is available, a hanger
support bar may be required (Fig. 4).
Quorum distributes approved hanger
support bars and outlet boxes.

Fig. 1

Ceiling Joists

Outlet Boxes

Fig. 2

Ceiling Joists

Outlet Box

Fig. 3

Ceiling Joists

Recessed Outlet Box

Fig. 4

Ceiling Joist

Hanger

Support Bar

Ceiling Joist

Outlet Box

Outlet Box

Ceiling

Wall

Transmitter

Canopy

Receiver

Fan

 Salon Inst -10_03-ok  6/9/2005  2:33 PM  Page 3