QM1004A-2-18 Combined RF Upconverter/Downconverter
User Manual
4.4 POWEr:RF [ON
|
OFF
|
1
|
0]
This command allows the user to turn on and off the RF power of the QM1004A-2-18.
When
0
or
OFF
is specified, the RF power is turned off.
When
1
or
ON
is specified, the RF power is turned on.
Syntax
:
POWE
:
RF
Space
"ON"|"OFF"|1|0
?
Example
:POWE:RF 0
This command turns off the RF power.
Default Condition
On power up, or when a
*RST
command is issued, the QM1004A-2-18 returns to the boot state’s setting.
The Combined RF Upconverter/Downconverter default setting is 0 for Master units and 1 for Slave units.
Query
:POWE:RF?
This query returns a 0 or 1 to indicated the Combined RF Upconverter/Downconverter
power state.
∙
0
is returned if the RF power is
OFF
∙
1
is returned if the RF power is
ON
Error Message
If the parameter is not in the recognized format, error
-102, "Syntax error"
occurs.
Quonset Microwave
Revision 1.4.3
50
Содержание QM1004A-2-18
Страница 7: ...QM1004A 2 18 Combined RF Upconverter Downconverter User Manual Quonset Microwave Revision 1 4 3 vi...
Страница 11: ...QM1004A 2 18 Combined RF Upconverter Downconverter User Manual Index 88 Quonset Microwave Revision 1 4 3 x...
Страница 41: ...QM1004A 2 18 Combined RF Upconverter Downconverter User Manual Quonset Microwave Revision 1 4 3 29...
Страница 103: ...Quonset Microwave www quonsetmicrowave com 1004 002 21 1004 002 21 Revision 1 4 3 May 2022...