Combined RF Upconverter/Downconverter
IEEE 488.2 Command Reference
7.9 *SAV
<
NRf
>
The
*SAV
(SAVe) command saves the current setup to non-volatile memory. There are 5 re-writeable
memory locations, specified by choosing an index between 1 and 5. Any of the 5 states can be re-
stored on startup when specified with the SYSTem:BOOTstate command. The parameters saved are the
Tune Frequency, RF Power State, LNA Power State, Reference Frequency, External Reference Enabled,
External Referece Switch Override, PLL Mode, Reference Divider, Upconverter Attenuation, and Down-
converter Attenuation
. For a detailed description of the parameters saved, see the relevent command
descriptions in this manual. NOTE: The MEM_CLR button on the back panel will rewrite the contents of
states 1-5 with the contents of state 0 when depressed, serving as a reset to factory defaults.
Syntax
*
SAV
Space
NRf
Allowed Values
The
NRf
parameter can be any integer in the range of 1 to 5.
Error Message
If the parameter is not in the recognized format, error
-102, "Syntax error"
occurs.
If the parameter is less than 1 or greater than 5, error
-222, "Data out of range"
occurs.
Quonset Microwave
Revision 1.4.3
80
Содержание QM1004A-2-18
Страница 7: ...QM1004A 2 18 Combined RF Upconverter Downconverter User Manual Quonset Microwave Revision 1 4 3 vi...
Страница 11: ...QM1004A 2 18 Combined RF Upconverter Downconverter User Manual Index 88 Quonset Microwave Revision 1 4 3 x...
Страница 41: ...QM1004A 2 18 Combined RF Upconverter Downconverter User Manual Quonset Microwave Revision 1 4 3 29...
Страница 103: ...Quonset Microwave www quonsetmicrowave com 1004 002 21 1004 002 21 Revision 1 4 3 May 2022...