Dual Channel RF Downconverter
IEEE 488.2 Command Reference
6.7 *RCL
<
NRf
>
The
*RCL
(ReCaLl) command restores a previously saved state from non-volatile memory. In addition
to factory default state 0, there are 5 re-writeable memory locations, specified by choosing an index be-
tween 1 and 5. The restored parameters are the
RF Power State, External LO1 Enabled, External LO2
Enabled, External Reference Enabled, Tune Frequency, Channel 1 Converter Mode, Channel 1 Attenua-
tor 1, Channel 1 Attenuator 2, Channel 1 ASR Enabled, Channel 2 Converter Mode, Channel 2 Attenuator
1, Channel 2 Attenuator 2, Channel 2 ASR Enabled
. For a detailed description of the parameters saved,
see the relevent command descriptions in this manual. When the *RCL command is called, these param-
eters will be applied to the device.
Syntax
*
RCL
Space
NRf
Allowed Values
The
NRf
parameter can be any integer in the range of 0 to 5.
Error Message
If the parameter is not in the recognized format, error
-102, "Syntax error"
occurs.
If the parameter is less than 0 or greater than 5, error
-222, "Data out of range"
occurs.
Quonset Microwave
Revision 1.0.0
77
Содержание QM1003-0.5-18-2
Страница 7: ...QM1003 0 5 18 2 Dual Channel RF Downconverter User Manual Quonset Microwave Revision 1 0 0 vi...
Страница 38: ...QM1003 0 5 18 2 Dual Channel RF Downconverter User Manual Quonset Microwave Revision 1 0 0 27...
Страница 100: ...Quonset Microwave www quonsetmicrowave com 1003 005 21 1003 005 21 Revision 1 0 0 March 2023...