3/8 

www.qundis.com Network 

Node 

WTT16 V22 

CE1N2874en 

 

 

09.09.2009 

RESET

MODE

DISPLAY

1

2

3

4

6

7

11

10

8

9

5

12

 

 

1.  Connector for M-bus service connection  
2.  Connector for enhancements 
3.  Screw terminal for the fixed M-bus connection 
4.  Connector for power supply DC 3,6 V 
5.  Connector for backup battery Indication of mains supply 
6.  Operating mode button (red) 
7.  Button for switching the display (blue) 
8.  Reset button (recessed) 
9. Display 
10.  Connector (not for the user) 
11.  Firmware memory (covered up) 
12. IrDA-Interface (optically) 

 
The wall-mounted section of the network nodes WTT16.. contains only the main battery. In 
variant WTT16.232 the RS232 interface is fixed here. The wall-mounted section of the net-
work nodes WTX16 and WTX16.232 contains the power pack and possibly an additional 
RS232 interface. 
 

GND

n.

c

.

RTS

CTS

Rx

Tx

4

2

7

3

5

6

1

 

1.  Mains connection L and N 
2.  Preinstalled mains cable (no flexible power cable!) 
3.  Extra insulation (shrink sleeve) 
4.  Connector for power supply DC 3,6 V 
5.  Screw terminal for the fixed M-bus connection 
6.  Connector for M-bus service connection 
7.  Indication of mains supply 

Wall-mounted section 

Содержание WTT16 Series

Страница 1: ...de is a component of the Q AMR system It has been designed for use in buildings to create a radio network for receiving and storing the data transmitted by the consumption meters installed in the buil...

Страница 2: ...WTX16 GSM and WTX16 IP are able to read M Bus meters according to EN13757 2 3 Technical design The network node consists of the following subassemblies transceiver for Q AMR network memory for 500 met...

Страница 3: ...11 Firmware memory covered up 12 IrDA Interface optically The wall mounted section of the network nodes WTT16 contains only the main battery In variant WTT16 232 the RS232 interface is fixed here The...

Страница 4: ...n also be started manually with the ACT26 service tool Installa tionsmode2 In installation mode the radio network will be built up automati cally Metering devices that transmit installation telegrams...

Страница 5: ...on of the device takes place and search mode starts Delete from version 2 2 for example If an already registered IrDA capable metering device is connected in IrDA master mode it can be removed from th...

Страница 6: ...voltage must be in the range from AC 100 to 240 V 50 60 Hz There is no protective earth PE connection Then cable strain relief must be provided by fitting cable ties Once the top section of the WT 16...

Страница 7: ...once to start the life expectancy calculation for the new main battery The backup battery MUST NOT be removed simultaneously A fatal loss of data would happen After storing the main battery for longe...

Страница 8: ...erating voltage WTT16 DC 3 6 V Lifetime of main battery 5 years Operating voltage WTX16 AC 100 240 V 50 60Hz Rated frequency 868 3 MHz Transmitter power 14 dBm Frequency of transmission 1 Perm ambient...

Отзывы: