background image

General information

A distance of less than 50 cm between the pumps and the module can 

infl uence the counting behaviour of the add-on radio module.
Metallized veneers (e.g. chrome) impair optimum radio reception. It is recom-

mended to replace existing chrome rosettes with „radio rosettes“. With this 

special rosette design, the shielding eff ect for radio waves is minimised.
Placing the add-on radio module on refl ective surfaces can lead to unwanted 

behaviour or errors.

Commissioning

Parameterization  

Before operation with a water meter prepared for radio communication, the add-on 

radio module must be parameterised with the meter parameters (meter number, 

meter reading and medium: cold or hot water and, if necessary, a diff erent billing 

date) of the associated mechanical water meter. For this purpose, the Q suite 5 

meter software in conjunction with the infrared communication head WFZ.IrDA-USB 

is required.

Registration in the radio network

New add-on radio modules are not radio active when delivered. To ensure radio 

transmission, built-in device combinations must be started by radio or registered in 

the radio system.

Depending on the type of radio system used, any system-related requirements for 

registering the device combination must be observed.

In the fi eld of AMR network technology, for example, the appropriate installation 

mode must be activated before starting the installation telegrams on the measuring 

device side.
The radio add-on module is activated by means of a programming stick / triggering 

tool Radio telegrams WFZ.PS, or alternatively by the measuring instrument software 

Q suite 5 in conjunction with the IrDA communication head WFZ.IrDA-USB.

Note

After activating the radio interface, the LED fl ashes slowly for about 4 minutes.

Safety information

The device may only be installed by trained specialist personnel. The device is 

maintenance-free.

For the non-replaceable lithium metal battery permanently installed in the unit, 

regulations for the transport of hazardous goods and for recycling as well as safety 

instructions for handling batteries must be observed.

Intended use

The unit is a top-mounted module with radio data transmission.

This product is used exclusively for retrofi tting mechanical water meters prepared 

for radio transmission for use in the Q walk-by and Q AMR systems.

Warranty and guarantee 

Warranty and guarantee claims can only be asserted if the equipment has been 

used for its intended purpose and applicable technical specifi cations and rules have 

been observed.

All uses not in accordance with the intended purpose automatically lead to a loss of 

claims.

Assembly and operating instructions

This product must be installed professionally and according to the specifi ed installa-

tion guidelines and may only be installed by trained and qualifi ed personnel.

EU Declaration of Conformity

QUNDIS GmbH hereby declares that the Q module 5.5 water add-on radio 

module complies with the directives 2014/53/EU and 2011/65/EU.

The complete text of the EU Declaration of Confor-mity is available 

at the following internet address:
https://qundis.com/service/downloads-and-information/ce-de-

clarations/

Disposal information

For the purposes of disposal, the device is considered a used electronics de-

vice in the sense of European directive 2012/19/EU and shall not be disposed 

of with household waste.

- Dispose of the device via the channels provided for this purpose.

- Observe the local and currently valid legislation.

- Dispose of used batteries at the designated collection points

.

QUNDIS GmbH 

Sonnentor 2

99098 Erfurt / Germany

Tel.: +49 361 26 280-0

Fax: +49 361 26 280-175 

Mail: [email protected] 

www.qundis.com

Technical data

Pulse value

1 litre/pulse

Radio mode

S-Mode (Q AMR, Q walk-by)

C-Mode (Q AMR, Q walk-by)

Radio frequency

S-Mode (868,30 +/- 0,30) MHz

C-Mode (868,95 +/- 0,25) MHz 

Radio frequency

S-Mode (max. 14 dBm / typ. 11 dBm)

C-Mode (max. 14 dBm / typ. 11 dBm)

Ambient environment

Transport

  -25 °C to +70 °C,

< 95 % relative humidity (without condensation) according to EN 60721-3-2

Storage

    -5 °C to +45 °C,

< 95 % relative humidity (without condensation) according to EN 60721-3-1

Operation

   +5 °C to +55 °C,

< 95 % relative humidity (without condensation) according to EN 60721-3-3

Weight

45 g

Protection type

IP65 according to EN 60529

Protection class

III according to EN 61140

Battery type

Lithium metal

Operating voltage

DC 3 V

Battery service life 

12 years ope 1 year r 6 months storage

Technical description

The add-on radio modules Q module 5.5 water Allmess transmit data from Allmess 

water meters type „Measuring capsule system MK +m“ and type „Domestic water 

meter V +m“ to the Q AMR and Q walk-by systems. The add-on radio modules can 

be used with the various meter designs.

3

2

1

 1

 Position of the optical interface (IrDA)

 2

 LED

 3

 Optical scanning

Front page

Backside

Remove empty module

To install a radio add-on module, the empty module must fi rst be removed.

1. Place a screwdriver in the positions.

2. Turn the screwdriver to open the lock of the empty module 

with the counter housing. This will separate the type plate at 

the perforation.

3. Remove the empty module.

4. Check the cover of the scanning disk before attaching the 

add-on radio module.

1. Place the add-on radio module fl ush on the water meter with 

an approx. 3 mm wide gap.

2. Push the add-on radio module against the counter housing 

with a little force after mounting.

3. The gap of approx. 3 mm closes. The add-on radio module 

must be fl ush all round! Please check!

4. To protect against manipulation, the add-on radio module should be secured with 

the enclosed adhesive seal made of security foil. For this purpose, the adhesive 

seal is used to connect the counter housing and the add-on radio module.

Glue the seal between two bars on the right-hand side so that the seal is not 

damaged when cylinders / rosettes are pushed on.

Securing the add-on radio module

The add-on radio module can be secured against accidental detachment from 

the water meter either with a rosette or with an optionally available mounting ring 

(mainly in mounting boxes).

Thus either the rosette together with the cylinder or only the mounting ring can be 

pushed on after the module has been installed.

Important notes on installation

The use of these add-on radio modules in areas with constantly high humidity 

(e.g. direct shower areas or shafts) should be avoided, as in the long term 

humidity can diff use through the plastic meter cover and impair readability 

and opto-electronic scanning. Furthermore, water meters must be installed 

frost-proof!

Mounting the add-on radio module

After removing the empty module, the radio add-on module can be mounted.

Note

To ensure trouble-free operation, the scanning disk should 

be clean and free of damage or scratches.

GB

Q module 5.5 water Allmess - Mounting and Installation Instructions

KUM4-ZZMO-DE0 ALMWA

10.11.20 / V 1.00

Housing features

Miscellaneous

Further information, such as detailed technical data, transport, 

recycling and safety instructions are available at the following 

Internet address:
https://qundis.com/service/downloads-and-information/

LED display

The red LED integrated in the add-on radio module serves to 

indicate the following operating states:

Installation

• 

Lights up for approx. 30 seconds after the add-on radio module 

has been placed on the water meter.

Water meter successfully detected

• 

The LED then fl ashes for about 5 minutes.

Disassembly / replacement

• 

After a short delay fast fl ashing for about 60 seconds.

LED