QOCS 5300
1. QOCS 5300 consists of two identical units and a flow divider.
2. The steps in section QOCS 2650 must be followed on each unit.
3. A flow divider must be installed on a wall at a level minimum 0.5 m above the condensate
treatment devices.
4. Use a spirit level to install the flow divider as level as possible. Otherwise, the inclined side
will have a preference and will receive higher flow than the other side.
5. The flow divider has two outlets, each of which must be connected to the condensate inlet of
the separate units. Make sure that there are no traps for condensate to collect.
Instruction book
18
2920 7197 51