1.5

Safety precautions during maintenance or repair

All responsibility for any damage or injury resulting from neglecting these precautions, or
non observance of the normal caution and care required for installation, operation,
maintenance and repair, even if not expressly stated, will be disclaimed by the
manufacturer.

1. Use only the correct tools for maintenance and repair work.
2. Use only genuine spare parts.
3. A warning sign bearing a legend such as "Work in progress - do not start" shall be attached

to the starting equipment, including all remote start equipment.

4. Persons switching on remotely controlled machines shall take adequate precautions to

ensure that there is no one checking or working on the machine. To this end, a suitable
notice shall be affixed to the remote start equipment.

5. Never use flammable solvents or carbon tetrachloride for cleaning parts. Take safety

precautions against toxic vapors of cleaning liquids.

6. Scrupulously observe cleanliness during maintenance and repair. Keep dirt away by

covering the parts and exposed openings with a clean cloth, paper or tape.

7. Never use a light source with open flame for inspecting the interior of the device.
8. All regulating and safety devices shall be maintained with due care to ensure that they

function properly. They may not be put out of action.

9. Before clearing the device for use after maintenance or repair, check that operating

pressures, temperatures and time settings are correct. Check that all control and shutdown
devices are fitted and that they function correctly.

10. Make sure that no tools, loose parts or rags are left in or on the device.
11. Never use caustic solvents which can damage materials of the device.

Also consult following safety precautions: 

Safety precautions during installation

 and

Safety precautions during operation

.

These precautions apply to electrical devices.
For precautions applying to the connected equipment consult the relevant instruction
book.
Some precautions are general and cover several machine types and equipment; hence
some statements may not apply to your machine.

Units and/or used parts must be disposed of in an environmentally friendly and safe
manner and in line with the local recommendations and legislation.

1.6

Dismantling and disposal

Dismantling

Once the end of life of the machine is reached, please follow next steps:

1. Stop the machine.
2. Check all safety precautions mentioned in the previous chapters to secure safe handling

(e.g. LOTO, cool-down, depressurize, discharge, ...).

3. Separate the harmful from the safe components (e.g. drain oil from oil containing parts).
4. Refer to the disposal topic mentioned below.

Instruction book

2920 7197 51

5

Содержание QOCS 106

Страница 1: ...Quincy Condensate management QOCS 25 QOCS 53 QOCS 106 QOCS 180 QOCS 360 QOCS 636 QOCS 1325 QOCS 2650 QOCS 5300 Instruction book...

Страница 2: ......

Страница 3: ...of the contents or any part thereof is prohibited This applies in particular to trademarks model denominations part numbers and drawings This instruction book is valid for CE as well as non CE labell...

Страница 4: ...R REPAIR 5 1 6 DISMANTLING AND DISPOSAL 5 2 General description 7 2 1 INTRODUCTION 7 2 2 OPERATION 7 3 Installation 12 3 1 DIMENSION DRAWINGS 12 3 2 INSTALLATION PROCEDURE 13 4 Operating instructions...

Страница 5: ...ion 1 Install the equipment where the ambient air is cool and as clean as possible Consult section Reference conditions and limitations 2 During installation or any other intervention on the equipment...

Страница 6: ...Persons switching on remotely controlled machines shall take adequate precautions to ensure that there is no one checking or working on the machine To this end a suitable notice shall be affixed to t...

Страница 7: ...with due care to ensure that they function properly They may not be put out of action 9 Before clearing the device for use after maintenance or repair check that operating pressures temperatures and t...

Страница 8: ...in symbol At the end of life time of the electric and electronic equipment EEE it must be taken to separate collection For more information check with your local waste authority customer center or dis...

Страница 9: ...vibration because of the use of filters and can be used with all types of drains The condensate meets the requirements of the environmental codes The number in the model designation is the air capacit...

Страница 10: ...let 1 into the mufflers 3 and is depressurized The condensate flows to the first stage and seeps through an oleophilic filter 4 which absorbs most of the oil The water from the first tower still conta...

Страница 11: ...o the first tower and seeps through an oleophilic filter 3 which absorbs most of the oil The water from the first stage still containing a small quantity of oil gradually flows to a second stage where...

Страница 12: ...2650 QOCS 5300 1 Condensate inlet 2 Mufflers 3 Oleophilic filters first stage 4 Service indicator oleophilic filter 5 Service indicator unit clogged 6 Drain 7 Organoclay filters second stage Instruct...

Страница 13: ...where an organoclay filter is fitted 7 The second stage filter starts to absorb the part of the oil in the condensate The condensate gradually flows into the third stage where another organoclay filt...

Страница 14: ...9 C mm 216 216 428 507 576 721 970 1000 1000 C inch 9 9 17 20 23 28 38 39 39 Shipping weight kg Organ oclay 2 4 3 0 7 5 11 17 32 56 115 240 Shipping weight lb 5 3 6 6 17 24 38 71 123 254 529 Operating...

Страница 15: ...e drains that are feeding it whenever possible The drain tube that is mounted to the outlet of the oil water separator must incline downwards over its entire length The reason for this is to avoid acc...

Страница 16: ...QOCS 25 QOCS 53 QOCS 106 QOCS 1325 QOCS 2650 Instruction book 14 2920 7197 51...

Страница 17: ...atic drain of the compressor condensate trap to the condensate inlet of the unit The connection can be made using one or both condensate inlets The piping diameter must be at least 6 mm for QOCS 25 53...

Страница 18: ...3 Check that the muffler is place properly and exactly below the condensate inlets 4 Pour clean water into the unit until the water comes out of the condensate outlet 5 Put the oleophilic filter on th...

Страница 19: ...Check that the muffler is place properly and exactly below the condensate inlets 6 Pour clean water into the unit until the water comes out of the condensate outlet 7 Put the oleophilic filter on the...

Страница 20: ...e the condensate treatment devices 4 Use a spirit level to install the flow divider as level as possible Otherwise the inclined side will have a preference and will receive higher flow than the other...

Страница 21: ...since every compressor installation can burden its separator in a variety of ways it is difficult to make a general prediction regarding the lifetime of the separator Therefore it is advised to check...

Страница 22: ...ch deteriorate the ability to break oil water emulsions 4 Remove the diffuser and pull out the mufflers See section Introduction 5 Fit the new mufflers and diffuser 6 Go to section Filter replacement...

Страница 23: ...QOCS 360 8102 0470 30 Manifold for QOCS 636 up to QOCS 5300 8102 0470 31 Wall mounting bracket for QOCS 25 QOCS 53 An optional wall mounting bracket is available to mount the unit on the wall Wall mou...

Страница 24: ...ment device Check the compressor FAD see section Technical data Cloudy condensate at the outlet Improper sizing It is possible that the compressor produces stable and strong emulsions due to various e...

Страница 25: ...Mild climate ambient temperature of 25 C 77 F and relative humidity of 60 Hot climate ambient temperature of 35 C 95 F and relative humidity of 70 Limitations for operation Minimum ambient temperature...

Страница 26: ...Hot climate l s 9 17 34 57 114 201 420 839 1678 Hot climate cfm 18 36 71 121 242 427 890 1779 3558 Correction factors For operation in conditions other than reference conditions multiply the compress...

Страница 27: ...Separation performance For an outlet oil carry over of 5 mg l instead of 10 mg l multiply the compressor capacity FAD in the tables above by 1 2 Instruction book 2920 7197 51 25...