background image

QK-DMMRDS 

ENGLISH 

 

 

 

 

 

WWW.QUIKO.BIZ 

 

1. 

GENERAL INFORMATION 

The 

QK-DMMRDS

 magnetic card reader has been designed to read information coded on magnetic bands in track 2 in accordance 

with ISO Standards and to translate said information into CLOCK and DATA signals according to a protocol largely employed in access 

control systems. The 

QK-DMMRDS

 reader can be interfaced with the access control units 

QK-DM20002, QK-DM40002 

 and  with all 

other compatible systems. 

Can be installed outdoors if suitably protected against the rain. 

 

2. 

MAIN TECHNICAL FEATURES 

 

Standard cards 

ISO 7811 track 2 

Reading mode 

F2F (FM) 

Power supply 

5 VDC ± 5% (without M/W30 converter) / 7÷12 VDC (with M/W30 converter) 

Maximum wiring distance 

100 m 

Consumption 

< 10 mA 

Card insertion speed 

125 - 1250 mm/s 

Average working life 

> 1,000,000 readings 

Dimensions and weight 

49 x 82 x 35 (WxHxD) - 336g 

 

3. 

WIRING 

The QK-DMMRDS reader can be directly connected to 

QK-DM40002 

control units configured with Dataclock type reading protocol.  

For the connection to the 

QK-DM20002

 control unit, or in cases where the configuration of the system requires the use of Wiegand 

type reading protocol, the MW30 converter must be inserted, connecting it at the minimum distance from the reader. 

The cable recommended for the connection of the QK-DMMRDS reader is STP class 5 or FTP class 5 or better. 

 
3.1  WIRING TO THE  CENTRAL UNITS QK-DM40002 WITH DATACLOCK PROTOCOL 

 

READER QK-DMMRDS 

GREEN (+5 VDC) 

BROWN (GROUND) 

WHITE (CLOCK) 

PINK (DATA) 

QK-DM40002 

– Gate 1 

GND 

D0.1 

D1.1 

QK-DM40002 

– Gate 2 

GND 

D0.2 

D1.2 

 

The central unit must be programmed assigning the Dataclock reader type to the Door. 

ATTENTION: The +5Vdc power supply is not available from terminal stripboard and must be supplied by an external power source or 

by connecting the reader to the MW30 converter as shown in Figure 1. 

 

3.2  WIRING TO THE CENTRAL UNITS QK-DM20002, QK-DM40002 

 

WITH WIEGAND PROTOCOL 

Connect the reader to the 

MW30

 converter as shown in Figure 2. Wire up the converter to the central unit according to the table below. 

The first row refers to the converter outputs as shown in Figure 2. 

 

MW30 

1 (+ VDC) 

2 (GROUND) 

3 (DATA 0) 

4 (DATA 1) 

QK-DM20002

 – Gate 1 

18 

15 

17 

16 

QK-DM20002

 – Gate 2 

QK-DM40002 

 – Gate 1 

+9 

GND 

D0.1 

D1.1 

QK-DM40002 

 – Gate 2 

+9 

GND 

D0.2 

D1.2 

The 

QK-DM20002

 control unit is already set up for the acknowledgement of the Wiegand type 30 bit protocol.                                                  

The 

QK-DM40002 

 control units must be programmed assigning the Wiegand type 30 bit protocol to the gate. Please refer to the 

control unit user manual. 

4. 

LED AND BUZZER MANAGEMENT 

The reader is fitted with RED and GREEN LEDs plus a buzzer for the signals. The LEDs must be controlLED from the outside by 

applying positive voltage (5-12VDC) to the respective control lines (YELLOW and GRAY wires, see figure). 

The buzzer must be control LED by connecting the control line to GROUND (CYAN wire, see figure). 

WARNING:  in  order  not  to  damage  the  reader,  connect  a  1  KOhm  resistance  in  series  to  the  control  lines  of  the  LEDs,  as 
shown in figure. 