QK-DMMRDS
ENGLISH
2
WWW.QUIKO.BIZ
1.
GENERAL INFORMATION
The
QK-DMMRDS
magnetic card reader has been designed to read information coded on magnetic bands in track 2 in accordance
with ISO Standards and to translate said information into CLOCK and DATA signals according to a protocol largely employed in access
control systems. The
QK-DMMRDS
reader can be interfaced with the access control units
QK-DM20002, QK-DM40002
and with all
other compatible systems.
Can be installed outdoors if suitably protected against the rain.
2.
MAIN TECHNICAL FEATURES
Standard cards
ISO 7811 track 2
Reading mode
F2F (FM)
Power supply
5 VDC ± 5% (without M/W30 converter) / 7÷12 VDC (with M/W30 converter)
Maximum wiring distance
100 m
Consumption
< 10 mA
Card insertion speed
125 - 1250 mm/s
Average working life
> 1,000,000 readings
Dimensions and weight
49 x 82 x 35 (WxHxD) - 336g
3.
WIRING
The QK-DMMRDS reader can be directly connected to
QK-DM40002
control units configured with Dataclock type reading protocol.
For the connection to the
QK-DM20002
control unit, or in cases where the configuration of the system requires the use of Wiegand
type reading protocol, the MW30 converter must be inserted, connecting it at the minimum distance from the reader.
The cable recommended for the connection of the QK-DMMRDS reader is STP class 5 or FTP class 5 or better.
3.1 WIRING TO THE CENTRAL UNITS QK-DM40002 WITH DATACLOCK PROTOCOL
READER QK-DMMRDS
GREEN (+5 VDC)
BROWN (GROUND)
WHITE (CLOCK)
PINK (DATA)
QK-DM40002
– Gate 1
-
GND
D0.1
D1.1
QK-DM40002
– Gate 2
-
GND
D0.2
D1.2
The central unit must be programmed assigning the Dataclock reader type to the Door.
ATTENTION: The +5Vdc power supply is not available from terminal stripboard and must be supplied by an external power source or
by connecting the reader to the MW30 converter as shown in Figure 1.
3.2 WIRING TO THE CENTRAL UNITS QK-DM20002, QK-DM40002
WITH WIEGAND PROTOCOL
Connect the reader to the
MW30
converter as shown in Figure 2. Wire up the converter to the central unit according to the table below.
The first row refers to the converter outputs as shown in Figure 2.
MW30
1 (+ VDC)
2 (GROUND)
3 (DATA 0)
4 (DATA 1)
QK-DM20002
– Gate 1
18
15
17
16
QK-DM20002
– Gate 2
9
6
8
7
QK-DM40002
– Gate 1
+9
GND
D0.1
D1.1
QK-DM40002
– Gate 2
+9
GND
D0.2
D1.2
The
QK-DM20002
control unit is already set up for the acknowledgement of the Wiegand type 30 bit protocol.
The
QK-DM40002
control units must be programmed assigning the Wiegand type 30 bit protocol to the gate. Please refer to the
control unit user manual.
4.
LED AND BUZZER MANAGEMENT
The reader is fitted with RED and GREEN LEDs plus a buzzer for the signals. The LEDs must be controlLED from the outside by
applying positive voltage (5-12VDC) to the respective control lines (YELLOW and GRAY wires, see figure).
The buzzer must be control LED by connecting the control line to GROUND (CYAN wire, see figure).
WARNING: in order not to damage the reader, connect a 1 KOhm resistance in series to the control lines of the LEDs, as
shown in figure.