CONNECTIONS TO TERMINAL BLOCKS 

1 .. MOTOR 1 POSITIVE INPUT N.1 (pedestrian) 
2 .. MOTOR 1 NEGATIVE INPUT N.1 (pedestrian) 
3 .. MOTOR 2 POSITIVE INPUT N.2 
4 .. MOTOR 2 NEGATIVE INPUT N.2 
5 .. FLASHING LAMP / COURTESY LIGHT OUTPUT 
6 .. OPEN GATE LAMP OUTPUT 
7 .. ELECTRIC LOCK CONNECTION. SEE APPOSITE PARAGRAPH 
8 .. COMMON OUTPUT FOR FLASHING LAMP / OPEN GATE LAMP / ELECTRIC LOCK 
9 .. POSITIVE INPUT FOR BACKUP BATTERY 
10 .. NEGATIVE INPUT FOR BACKUP BATTERY 
11 .. POSITIVE  12 / 24VCC FOR ACCESSORIES POWER SUPPLY 
12 .. COMMON OUTPUT FOR LAMP AND OPEN GATE LAMP

 

M2 

13 .. PHOTOCELL TEST AND EMERGENCY CONTROLS 
14 .. START INPUT (NO contact) 
15 .. PEDESTRIAN START INPUT (NO contact) 
16 .. SAFETY EDGE INPUT (NC contact) 
17 .. STOP INPUT (NC contact) 
18 .. PHOTOCELL INPUT N.1 (NC contact) 
19 .. PHOTOCELL INPUT N.2 (NC contact) 
20 .. M1 OPENING LIMIT SWITCH (NC contact) 
21 .. M1 CLOSING LIMIT SWITCH (NC contact) 
22 .. M2 OPENING LIMIT SWITCH (NC contact) 
23 .. M2 CLOSING LIMIT SWITCH (NC contact) 
24 .. COMMON OUTPUT FOR PHOTOCELLS - START - STOP – LIMIT SWITCHES

 

M3 

25 .. ANTENNA POSITIVE INPUT 
26 .. ANTENNA NEGATIVE INPUT

 

  
IMPORTANT:       

J1 MUST BE CLOSED FOR 12VDC MOTORS 

                             J2 MUST BE OPEN FOR 12VDC MOTORS

 

 

DIP SW1 MANAGEMENT 

Do the settings when gate is closed

 

DIP 

ON 

OFF 

DIP1 

Learning Time 

Normal operation 

DIP2 

Hold to run command function enabled 

Hold to run command function disabled 

DIP3 

Step by step without automatic closing 

Automatic closing enabled 

DIP4 

Community mode: after the first opening start signal 
the gate doesn’t accept other start signals. Gate will 
close automatically.  

Community mode disabled 

DIP5 

Function for engaging electrical lock (2 seconds at 
maximum pressure at the end of closing) enabled. 

Function for engaging electrical lock disabled. 

DIP6 

Obstacle sensing function will stop the gate and 
reverse it for 3 seconds when detecting obstacle 

Obstacle sensing function will stop the gate when 
detecting obstacle 

DIP7 

Slow down time = 3 seconds 

Slow down time = 5 seconds 

DIP8 e 9 

Slowdown Rate See table below 

Slowdown Rate See table below 

DIP10 

1 leaf gate functioning  

2 leafs gate functioning 

 

SLOW DOWN TABLES 

 

DIP8 - DIP9 SW1 Do the settings when gate is closed 

 

Off - Off = Slow down is disabled 
On - Off = High slow down 
On - On = Medium slow down 
Off - On = Low slow down 

 

DIP SW2 MANAGEMENT 

Do the settings when gate is closed 

DIP 

ON 

OFF 

DIP1 

Disables M2 closing limit switch input (FCC2) 

Enables M2 closing limit switch input (FCC2) 

DIP2 

Disables M2 opening limit switch input (FCA2) 

Enables M2 opening limit switch input (FCA2) 

DIP3 

Disables M1 closing limit switch input (FCC1)  

Enables M1 closing limit switch input (FCC1) 

DIP4 

Disables M1 opening limit switch input (FCA1) 

Enables M1 opening limit switch input (FCA1) 

DIP5 

Disables FOTO2 (opening and closing photocell) 

Enables FOTO2 (opening and closing photocell) 

DIP6 

Disables FOTO1 (closing photocell) 

Enables FOTO1 (closing photocell) 

DIP7 

Disables STOP input 

Enables STOP input 

DIP8 

Enables rapid re-closing after 3” 

Disables rapid re-closing 

DIP9 

Setting Battery Voltage = 12 VDC 

Setting Battery Voltage = 24 VDC 

DIP10 

Enables Courtesy Light + 3 Minutes on Terminal 5 

Disables Courtesy Light 

 
OBSTACLE SENSING ADJUSTMENTS (default set to half threshold) 

Rotating the PT1 and PT2 trimmer clockwise increases the obstacle sensing of the respective motor. (From 0.5 to 7.0 A). 
PT1 = M1 / PT2 = M2 
The operation of the amperometric in both opening and closing causes the immediate stop of the movement or anti-crash 
with release of the obstacle (function selectable with DIP6 SW1) 
If slowdowns are used, during this phase, the obstacle sensing is automatically set to fixed values so as not to risk false 
operations. 

 

If the system is not equipped with electrical limit switches, set DIP6 SW1 to ON. This is to avoid the risk that the ground 
stopper or the meachnical limit switch of motor is detected as on obstacle. 
 
To disable obstacle sensing function rotate PT1 and PT2 totally clockwise. 

 

CONNECTING ELECTRIC LOCK TO 12V SYSTEMS WITH OR WITHOUT BATTERY:  

Connect the two ends of the electric lock to terminal 7 "lock" and to terminal 8 "com" 

 

CONNECTING ELECTRIC LOCK TO 24V SYSTEMS WITHOUT BATTERY:  

If we have a 12V electric lock on 24V systems connect a pole of the electrical lock to terminal 7 
"Lock" and the other pole on the transformer (12V) wire. 

 

CONNECTING ELECTRIC LOCK TO 24V SYSTEMS WITH BATTERY:  

If we have a 12V electric lock on 24V systems, connect an electric lock pole to terminal 7 "lock" and the other pole on the 
two battery series (= 12V). 

 

TEST INPUT 

In  the  programming  phase,  a  photocells  presence  and  operation  control  is  performed:  this  is  done  by  removing  power 
from photocell TX (must be powered by the POSITIVE terminal 13) 
If  the  presence  of  the  photocells  is  detected  during  this  phase,  the  control  unit  controls  the  proper  functioning  of  the 
photocells before each gate movement. In the event that the photocells are not present at time of programming, but there 
was a closing jumper or otherwise powered, the control panel does not perform controls by automatically excluding the 
input. 

 

BATTERY INPUT 

The control unit is equipped with a battery input directly supervised by the micro-controller which determines its vitality; 
The charging cycle starts if it reads the battery discharge value, otherwise the battery is not charged to prevent abnormal 
use. We recommend that you use 12V 2 or 7 Ah rechargeable batteries. In the 24V version use two batteries in series. 

 

WATCH FUNCTION 

Using terminals 14 and 24, you can connect a TIMER to program programmed gate openings. 
The timer contact must be NO type and must remain closed for as long as the gate remains open. 
If there is already a connection to terminal 14, connect it in parallel. 

 

AUTOMATIC CLOSURE ON POWER RETURN 

If automatic closing is enabled and, before removing electricity or electricity black out is faced, the gate was not closed, 
once the control board is powered again, it will automatically close the gate. 

 

PREFLASHING 

Pre-flashing function is fixed at 3 seconds  
 

OPEN GATE LAMP 

Closed Gate = Lamp is Off  

 

 

Gate not closed = Lamp is On 

 

SAFETY EDGE INPUT 

The  control  unit  is  predisposed  for  controlling  safety  edges.  On  this  input  you  can  connect  either  the  NC  or  the  8k2 
inductive safety edges. The controller during the time learning phase controls the input, if there are any connected safety 
edges, it stores both mechanical and inductive values. If you do not connect any type of safety edge, bridge the “COSTA” 
input with terminal 24 "com". 
 

RAPID CLOSING FUNCTION: 

This  function  allows  you  to  reduce  the  pause  time  to  3  seconds  from  the  operation  and  release  of  the  photocells.  To 
enable this function, bring DIP8 SW2 to the ON position. 

 

REMOTE CONTROL CODE LEARNING (ATTENTION: TO BE PERFORMED WHEN THE GATE IS CLOSED ONLY) 

Press  the  P1  key,  the  "prog"  programming  LED  lights  up  to  indicate  that  the  control  panel  is  ready  to  learn  a  remote 
control (regardless of the type DIP or Rolling-Code code). Now you can press one of the keys of a transmitter (1-3 or 4). 
Button 2 only for pedestrian start. The prog led on the board gives a blink to confirm the remote control code is stored 
correctly. Wait unitil the prog led lights off and start using the remote control. If you have other remotes codes to store, do 
it in the same procedure before the prog led lights off or repeat sequence again. 
              