quiko QK-CE220WRL Скачать руководство пользователя страница 2

 2 

www.quikoitaly.com 

Anemometer :

 manually turn the Anemometer blades; at the 

same time, the control unit will cause an upward movement 
lasting 5 seconds. 

Sun sensor : 

turn the VR1 trimmer as far as possible in a 

clockwise direction (in the + position); at the same time, the 
control unit will cause the SUN LED to light up and there will be 
a downward movement lasting 5 seconds. Turn the VR1 trim-
mer in an anticlockwise direction (in the – position); at the same 
time, the control unit will cause the SUN LED to switch off and 
there will be an upward movement lasting 5 seconds. 

Rain sensor : 

get the sensitive part of the Rain Sensor wet; at 

the same time, the control unit will cause the RAIN LED to light 
up and there will be an upward movement lasting 5 seconds. 
When you have completed the test, make sure you have dried 
the sensitive part of the rain sensor before using the control unit 
in the normal operation mode. 

P

ROGRAMMING 

B

UTTONS AND 

I

NDICATOR 

L

EDS

 

SEL button:

 selects the type of function to store; selection is 

indicated by the LED flashing. The desired function can be se-
lected by pressing the button repeatedly. The selected function 
remains active for 15 seconds (flashing LED) following which 
the control unit returns to its original status.

 

SET button:

 programmes the function that has been selected 

using the SEL. Key.

 

Indicator LEDs

 

LED on: option stored.

 

LED off: option not stored.

 

Flashing LED: option selected. 

---------------------- MAIN MENU -----------------

Reference LED                LED Off                              LED On

1) CODE                          No code                              TX Pgm code
2) T. MOT.             Motor time 2 minutes              Pgm motor time
3) WIND SPEED    Wind safety 25 km/h              Pgm. Wind safety           
4) SUN SENSOR   Sun sensor = OFF                 Sun sensor = ON
5) RAIN SENSOR   Rain sensor = OFF               Rain sensor = ON
6) SUN                   Sun Presence = No               Sun Presence = Yes       
7) RAIN                  Rain Presence = No              Rain Presence = Yes      
8) R. HEAT            R. Heat = No                          R. Heat = Yes                 

1) CODE 

( Radio control programming )

 

Programming using a 3 button radio control from the QK-
TXTUB/ QK-TXTUB3/ QK-TXTUB6. 

The control unit allows you to store the whole QK-TXTUB/ QK-
TXTUB3/ QK-TXTUB6 radio-control by programming only the 
UP button. 

 

To programme the QK-TXTUB/ QK-TXTUB3/ QK-TXTUB6 ra-
dio-control codes, follow this procedure: press the SEL key; the 
CODE LED begins to flash. Press the UP key of the desired 
radio control at the same time; at that moment, the CODE LED 
will remain lit and programming will be complete. If all of the 
possible 10 radio control codes have been stored and you re-
peat the programming operation, all indicator LEDs will start 
flashing very rapidly to indicate that no new codes can be 
stored.

 

Deleting the codes 

To delete all transmission codes 

stored in the memory, proceed as follows: press the SEL but-
ton; the CODE LED starts flashing. Then press the SET button; 
the CODE LED switches off and the procedure is complete.

 

2) T. 

MOT. 

( Motor Timer Programming  )

 

The control unit comes with a motor power supply time of two 
minutes (T. MOT. LED OFF). 
The motor time must be programmed when the shutter is down 
and in the following way: 
Press the SEL key until the T. MOT LED key flashes, then hold 
down the SET key; the shutter will begin to move upwards. 
Once the desired position has been reached, release the SET 

key – at this very moment, the motor time will be stored and the 
T. MOT LED will remain lit. 
If you are using an automation which has a stop limit, we rec-
ommend that you set a time which exceeds the stop limit of the 
shutter by a few seconds. 
If you want unlimited motor time, perform the same program-
ming procedure, holding down the SET key for less than two 
seconds; the T. MOT LED will remain lit and the unlimited time 
function will be set. The operation may be repeated if a mistake 
is made during programming. 

3) WIND 

( Wind Safety Threshold Programming )

 

Displaying the programmed wind threshold 

The wind safety threshold may be displayed in the following 
way: use the SEL key to navigate to the WIND LED position; 
the LED will double-flash the same number of times as the 
stored wind safety threshold (each WIND LED double-flash cor-
responds to an increase of 5 km/h), (for example:

 5 WIND LED 

flashes = 25 km/h).

 

 
Wind safety threshold selection from 5 to 40 km/h 

The control unit comes with a default wind safety threshold set-
ting of 25 km/h (WIND LED OFF). 
The wind safety threshold may be programmed in the following 
way: use the SEL key to navigate to WIND LED, then press the 
SET key to start the programming procedure: At the same time 
the WIND LED will begin to double-flash (each double-flash of 
the WIND LED corresponds to an increase of 5 km/h); press 
the SET key once the desired threshold has been reached – at 
this moment, the selected value will be stored and the WIND 
LED will remain lit (

for example: 5 WIND LED double-flashes = 

25 km/h).

 

The operation may be repeated if a mistake is made during 
programming. 
 

4) SUN 

SENSOR 

( Sun Sensor ON/OFF )

 

Enabling the Sun Sensor 

The control unit comes with the Sun Sensor disabled (SUN 
SENSOR LED OFF). 
The Sun Sensor may be enabled in the following way: press the 
SEL key until the SUN SENSOR LED flashes, then press the 
SET key briefly; at this moment the SUN SENSOR LED re-
mains lit and the Sun Sensor will be enabled. Repeat the op-
eration to disable the Sun Sensor. 

Enabling the Sun Sensor using a 3-button radio control 
(QK-TXTUB/ QK-TXTUB3/ QK-TXTUB6): 

The Sun Sensor may be enabled in the following way: hold 
down the (+) key on the radio control that was programmed 
previously for 5 seconds; at the same time the control unit will 
cause the shutter to move Up/Down for 1 second to confirm 
that the Sun Sensor has been enabled, and the SUN SENSOR 
LED will remain lit. Repeat the operation to disable the Sun 
Sensor by following the same procedure, but instead holding 
down the (-) key for 5 seconds. 

5) RAIN 

SENSOR 

( Rain Sensor ON/OFF )

 

Disabling the Rain Sensor 

The control unit comes with the Rain Sensor enabled (RAIN 
SENSOR LED ON). 
The Rain Sensor may be disabled in the following way: press 
the SEL key until the RAIN SENSOR LED flashes, then press 
the SET key briefly; at this moment the RAIN SENSOR LED 
switches off and the Rain Sensor will be disabled. You can re-
peat the operation to enable the Rain Sensor. 

 

 

 

 

 

 

Содержание QK-CE220WRL

Страница 1: ...motor s Up ward movement wire and the Downward movement wire GROUP OR GENERAL CENTRALISATION It is also possible to enter two identical codes buttons from one radio control onto all the control units or a group of them which are situated at a maximum distance of 20 metres from the point of command in order to obtain general or partial mo tion of more than one automation ANEMOMETER OPERATION The el...

Страница 2: ...wing way Press the SEL key until the T MOT LED key flashes then hold down the SET key the shutter will begin to move upwards Once the desired position has been reached release the SET key at this very moment the motor time will be stored and the T MOT LED will remain lit If you are using an automation which has a stop limit we rec ommend that you set a time which exceeds the stop limit of the shut...

Страница 3: ...Automatic Movement Lock dis abled to enable the function proceed as follows check that the extended menu is enabled SUN RAIN and R HEAT LEDs flash using the SEL key navigate to T MOT LED when flashing and press the SET key the T MOT LED lights up permanently and programming is completed Repeat the opera tion to restore the previous configuration C WIND Safety Upward Movement The control unit is su...

Страница 4: ...nst accidental closures For connections power supply and outlet contact we rec ommend the use of flexible wires with an insulating sheath in harmonised polychloroprene H05RN F The wires should have a minimum cross section of 0 75 mm 2 Fasten the connection cables using the cable clamp sup plied with the product kit Handle the control unit with care during the installation process and make sure tha...