 Electronic Control Unit 

 QK-CE220WRL 

An electronic control unit integrated into the Wind, Sun and 
Rain Sensor compartment, for the automation of sun blinds and 
rolling window shutters, with the possibility of radio control op-
eration for individual and/or centralised control. 

T

ECHNICAL DATA

 

- Power supply: 

230V~  50/60Hz  600W Max.

 

- Motor output                            : 

230V~  500W Max.

 

- Operating temperature: 

-10

÷

55°C

 

- Radio receiver                         : 

433,92 MHz  

- Compatible radio controls: 

12-18 Bit or Rolling Code

 

- Anemometer sensitivity:                                  5 

÷

 40 Km/h

 

- Sun sensor sensitivity:                                    5 

÷

 40 Klux

 

- Number of codes that may be stored:                     10 Max.                     

 

- Packaging dimensions:                                  240 x 185 x 110 
mm.

 

- Container:                                         PC UL94V-0 (IP54)

 

C

ONNECTION OF 

CN

 

1

 

T

ERMINAL BOARD

 

1: Earth. 
2:  230 V line input (Phase). 
3:  230 V line input (Neutral). 
4:  Upward movement motor output. 
5:  Shared motor output. 
6:  Downward movement motor output. 

I

NITIAL 

O

PERATING CONDITION

 

The device can only operate in conjunction with one or more 
radio controls. There is no radio control code stored in the de-
fault factory setting.

 

O

PERATION USING DIFFERENT 

M

ODELS OF 

R

ADIO 

C

ONTROL

 

Operation using a 3-button radio control (QK-TXTUB): 

The following type of operation is obtained using the QK-
TXTUB radio control: the (Up) button controls the upward 
movement until the end of the motor time, the (Stop) button 
causes all movement to stop and the (Down) button controls 
the downward movement. If a stop command is sent during the 
upward or downward movement, the control unit causes this 
movement to stop. If a command that is in the opposite direc-
tion to the current movement is sent during the upward or 
downward movement, the control unit causes the shutter to 
change direction.

 

Operation using a 3-button radio control (QK-TXTUB3/ QK-
TXTUB6):

 

When using the QK-TXTUB3/ QK-TXTUB6 radio control, you 
will obtain the same operation as previously described for the 
QK-TXTUB version; in addition, by using the keys (-) and (+) at 
the sides of the radio control it is possible to select the UP – 
STOP – DOWN controls for 3 different types of use (QK-
TXTUB3) or for 6 different types of use (QK-TXTUB6). In addi-
tion, by using the keys (-) and (+) at the sides of the radio con-
trol it is possible to enable and disable the sun sensor (the se-
lection is confirmed by a quick UP / Down movement of the mo-
tor).  

 

I

NVERSION OF THE ROTATION MOTOR

 

If you notice that when pressing the UP key on the radio-control 
the control unit causes the shutter to move upwards instead of 
downwards, simply repeat the programming procedure pressing 
the DOWN key instead of the UP key, or invert the motor’s Up-
ward movement wire and the Downward movement wire. 

 

 

 

 

G

ROUP OR 

G

ENERAL 

C

ENTRALISATION

 

It is also possible to enter two identical codes ( buttons ) from 
one radio control onto all the control units or a group of them 
which are situated at a maximum distance of 20 metres from 
the point of command, in order to obtain general or partial mo-
tion of more than one automation. 

A

NEMOMETER 

O

PERATION

 

The electronic control unit will cause the sun shade to move 
upwards every time the wind exceeds the selected threshold. 

S

UN 

S

ENSOR 

O

PERATION

 

The electronic control unit controls the downward movement of 
the sun shade after 5 minutes during which the brightness is 
greater than the threshold selected using the VR1 trimmer and 
displayed when the SUN LED lights up; it also controls the up-
ward movement of the shade after 5 minutes during which the 
brightness is below the selected threshold.  

Sun sensitivity adjustment ( 5 ÷ 40 Klux ) 

The control unit allows you to adjust the sensitivity of the Sun 
Sensor using the VR1 trimmer. When the SUN LED lights up 
on the control unit, this indicates that the intensity of the sun 
exceeds the selected threshold; this enables you to use the cur-
rent light conditions as a reference when setting the desired 
value. 

R

AIN 

S

ENSOR 

O

PERATION

 

The electronic control unit will cause the sun shade to move 
upwards as soon as the sensitive part of the rain sensor gets 
wet with water as displayed when the RAIN LED lights up. 

 

O

PERATION PRINCIPLES

 

       SW1               SW1                SW1               SW1 

 

Step-by-step   P/P + Aut Sensors     User Present        Sensor Test 

 
1) Step-by-step (Dip 1 and 2 OFF)

 

The electronic control unit has a cyclic "Step-by-Step" logic, 
whose operation depends on the type of radio control associ-
ated with. 

2) Step-by-step + Aut. Sensors  (Dip 1 ON and Dip 2 OFF)

 

The electronic control unit allows the "Step-by-Step" operation 
as described above, with the addition of the automatic control of 
the Wind and Rain sensors. After the activation of one of the 
two sensors, once the disturbance is over, the electronic control 
unit controls the downward movement of the sun shade after 5 
minutes. 

3) Manually-controlled (Dip 1 OFF and Dip 2 ON)

 

Using the radio control the “User present” operating mode can 
be obtained, i.e. the control must be constantly enabled so that 
the blind or shutter can be moved as necessary. The movement 
stops when the control is released.

 

4) Sensor Test (Dip 1 and 2 ON) 

The electronic control unit allows to check the sensor operation 
and the correct rotation direction upon installation; we advise 
that you place the shade in intermediate position in order to ver-
ify the confirmation movements during the tests. 

 

Warning: after you have tested the sensors, restore the Dip 1 
and 2 in the desired operation mode. 

GB 

Содержание QK-CE220WRL

Страница 1: ...motor s Up ward movement wire and the Downward movement wire GROUP OR GENERAL CENTRALISATION It is also possible to enter two identical codes buttons from one radio control onto all the control units or a group of them which are situated at a maximum distance of 20 metres from the point of command in order to obtain general or partial mo tion of more than one automation ANEMOMETER OPERATION The el...

Страница 2: ...wing way Press the SEL key until the T MOT LED key flashes then hold down the SET key the shutter will begin to move upwards Once the desired position has been reached release the SET key at this very moment the motor time will be stored and the T MOT LED will remain lit If you are using an automation which has a stop limit we rec ommend that you set a time which exceeds the stop limit of the shut...

Страница 3: ...Automatic Movement Lock dis abled to enable the function proceed as follows check that the extended menu is enabled SUN RAIN and R HEAT LEDs flash using the SEL key navigate to T MOT LED when flashing and press the SET key the T MOT LED lights up permanently and programming is completed Repeat the opera tion to restore the previous configuration C WIND Safety Upward Movement The control unit is su...

Страница 4: ...nst accidental closures For connections power supply and outlet contact we rec ommend the use of flexible wires with an insulating sheath in harmonised polychloroprene H05RN F The wires should have a minimum cross section of 0 75 mm 2 Fasten the connection cables using the cable clamp sup plied with the product kit Handle the control unit with care during the installation process and make sure tha...

Отзывы: