TECHNICAL SPECIFICATIONS
Power
Power engine
Output accesories
Time for automatic close
Time for maneuver
Time for slow down
Time for courtesy light
Nr codes storable
Transmitters type
Frequency
Temperature to work
Sensibility
Homologation
230V AC +/- 10%
550 W
24V AC 250mA
5 a 120 sec
3 a 120 sec
2 a 120 sec
180 sec
254 code
Fix\Roll-code
433.92 / 868 Mhz
-20 a 70°C
Better of –100dBm
Conf ETS 300-220/ETS 300-683
Terminal Tip.
Description
1 - 2com
NO
START CONTACT (Each impulse OPEN/STOP/CLOSE/STOP)
3 - 2com
NO
PEDESTRIAN CONTACT
4 - 6com
NC
SAFETY BAND OR OPENING PHOTOCELLS (If no use make bridge)
5 - 6com
NC
CLOSING PHOTOCELLS (If no use make bridge)
7 - 6com
NC
STOP contact(If no use make bridge)
9 - 8com
NC
LIMIT SWITCH OPENING
10 - 8com
NC
LIMIT SWITCH CLOSING
11 - 12
24V ~
Power service or accessories (output 24Vac 250mA)
13-14-15
230V ~
Input ENGINE (13-14 input phases with capacitor in parallel) (15 common)
16 - 18
230V ~
FLASH
17 - 18
230V ~
COURTESY LIGHT
19 - 20
230V ~
Input POWER 110Vac
21 - 22
/
GROUND
23 - 24
Input ANTENNA ( 24 signal)
5 6
11 12
Example wiring photocells
Start Stop
2 1
7 6
Example wiring selector
CONTACT
NO
CONTACT
NC
+ -
NC COM
+ -
TX
RX
BUTTON
P1
or
RADIO PROG
for storage the transmitter
BUTTON
P2
or
PROG TIME
for storage the stroke
TRIMMER T1
The trimmer POWER regulates the torque and sensitivity during the maneuver
TRIMMER T2
The trimmer POWER SLOW regulates the torque and sensitivity during SLOW DOWN phase
-
+
The TORQUE increases turning the trimmer in clockwise sense.
L1
Led STATUS
Lit when the unit is powered
L2
Led RADIO
Lit when accessing in radio storage
L3
Led PROG. TIME
It is blinking when in programming
L4
Led START
Lit when taking a pulse
L5
Led PEDESTRIAN
Lit when taking a pedestrian pulse
L6
Led PHOTOCELLS
Lit when the fotocells are aligned
L7
Led L.S. OPENING
Lit when limitswitch opening is on NC
L8
Led L.S. CLOSING
Lit when limitswitch closing is on NC
L7+L8
Led STOP
Both on when the stop is on NC
L9
Led PHOTOCELLS
AP/ safety edge
Lit when the photocells are aligned/
safety edge connected
TABLED LEDS
ENCODER OPERATION
Actived by
DIP8 ON
CHANGE OF SENSITIVITY AND TORQUE
More torque =
less sensitivity
Less torque =
more sensitivity
The parameters are set by
the trimmer T1 and T2.
COM
N.C
.
N.C.
N.C.
N.O.
N.O.
N.C.
COM
N.C.
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18 19 20 21 22
STOP
L5
L6
L7
L8
PED
START
ANT
24Vac
LSO
LSC
LSO
FUSE
ENCO
DER
PH
M
BLK COURT230Vac
23 24
L4
L9
PH2
PED
START
ON
1 2 3 4 5 6 7 8 9 10
P1
P2
PROG
TIME
PROG
RADIO
L3
L2
POWER
POWER
SLOW
T1
T2
STOP
PH2 PH
LSC
L1
Our products if installed by qualified personnel capable to evaluate
risks, comply with norms UNI EN 12453, EN 12445
UNI
EN
The CE mark complies with EEC European directive 89/336
+ 93/68 D.L.04/12/1992 n.476
QK-CE220CN
Control board for 230V gearmotors
USER MANUAL V01