background image

1-888-QUIETCOOL

13

4. WIRING

NOTE:

 Wiring Diagrams are for examples only and wiring should be done 

by an experienced electrician. 12 or 14-gauge romex is common. Check your local building 
code before choosing the wire type.

4-1.  Single Speed Wiring

For wiring of the TRI PRO-1.5 with one speed.

4-2.  Two Speed Wiring

For wiring of the TRI PRO-2.5, 3.3, 4.8, and 5.5 with two speeds.

4-3.  Four Speed Wiring

For wiring of the TRI PRO-6.5 with four speeds.

NOTE:

 QuietCool whole house fans can be used with the included power cord with a plug 

outlet, but will only operate on high speed. The system will also work with a wireless 
system using the power cord. The main purpose of the power cord is to test fan 
operation.

 

4-1  Single Speed Wiring (for TRI PRO-1.5) 

1. 

For this installation, you will need (2) 2 wire Romex, single-gang retrofit box, and an 8 Hour Timer. 
Using the included wire nuts, tie the black wire from the first 2 wire Romex from the power source to 
the black wire on the timer. 

(see Figure A)

 

2. 

Using a wire nut, tie the black wire on the 2 wire Romex from the fan to the red wire on the timer. 

3. 

Using a wire nut, tie the bare copper wires together with the green ground wire on the timer. 

4. 

Using a wire nut, tie the white common wires from the Romex to the white common wire on the timer. 

5. 

Begin wiring the fan by opening up the handy box. Take off the wire nuts within the handy box. 
Unscrew the green ground wire. Detach the green ground wire from the power cord. 

Remove the 

power cord.

 Re-attach the ground screw and wire to the handy box. Cut your green ground wire in 

half and strip both sides. 

(see Figure B) 

 

Содержание TRI PRO-1.5

Страница 1: ...YSTEMS COM 1 SEE HEAR FEEL THE QUIETCOOL DIFFERENCE ADVANCED WHOLE HOUSE FANS OWNER S GUIDE TRIDENT PRO LINE DO NOT THROW AWAY SERIAL NUMBER FOR FAN IS LOCATED ON BACK COVER OF OWNER S GUIDE LEAVE WITH HOMEOWNER ...

Страница 2: ...uated away from heat sources 7 Damage Requiring Service Only qualified service personnel should service the QuietCool system The user should not attempt to service the product CONTENTS 1 QUICKSTART GUIDE 3 1 1 Special Instructions 3 1 2 Product Diagram 4 1 3 When to Run Fans 5 1 4 Where to Start Cooling 5 1 5 Indoor Air Quality 5 2 SYSTEM OVERVIEW 6 2 1 Introduction 6 2 2 Features 6 2 3 System Ven...

Страница 3: ... wire the product Product warranty does NOT cover defective motors resulting from wiring errors 4 DO NOT use any QuietCool ducted whole house fan in a home with all closed windows 5 TEST your QuietCool unit before installation using included power cord If the fan does not work call us immediately Special Instructions to Contractors 1 DO NOT take the Owner s Guide with you after the installation Th...

Страница 4: ...n system E Hand guard Added for safety to keep hands out of the motor housing F Acoustical Duct R 4 2 acoustically lined duct for quiet operation G Damper Box Mounts to the ceiling and houses the damper doors to keep the home insulated H Damper Doors R 5 lined damper doors to prevent air movement between the home and attic I Removable Grille Aesthetically pleasing removable egg crate ceiling grill...

Страница 5: ...too many windows will lessen the cooling breeze you feel The breeze will flow through your home and make its way to each QuietCool you have in operation As it gets later in the evening and even cooler outside you can begin to open windows in other rooms of your home to prepare for bedtime Then when it s time for bed you should close all the windows in your main living space but leave the windows i...

Страница 6: ...e fans average at just around 45 dB that s equivalent to quiet conversation The QuietCool system uses a cutting edge patented design to get our sound levels down to a respectable level Our fans suspend in the attic and use an acoustical duct that connects to a ceiling box and grille The result is an easy installation and quiet operation Once the air outside is cooler than the indoor air crack open...

Страница 7: ... But don t worry the system will still operate if there is not enough venting Insufficient venting is a very simple problem to fix Roofing contractors can add extra venting to most homes simply and easily The most common types of venting is shown in the chart below RECOMMENDED VENTILATION 1 SQ FT FOR EACH 750 CFM Vent Type Model Type Average Size Venting Sq Ft Gable vent 12 x 19 5 1 20 Dormer Vent...

Страница 8: ...driver with you Make sure the template fits between the framing The template size varies depending on which model of QuietCool fan you are installing QuietCool Fan Model Template Size TRI PRO 1 5 14 1 4 x 14 1 4 TRI PRO 2 5 14 1 4 x 18 1 4 TRI PRO 3 3 14 1 4 x 22 1 4 TRI PRO 4 8 TRI PRO 5 5 14 1 4 x 30 1 4 TRI PRO 6 5 14 1 4 x 36 1 4 2 When you have chosen your exact spot place the provided templa...

Страница 9: ... the ceiling cut out hole TIP If your attic access is far from your fan location you can remove the duct from the motor housing and pass the motor housing duct and damper box through the ceiling cut out hole and reattach the duct to the motor housing in the attic 7 Hang the motor head from the rafters by fastening the metal strapping that is attached to the motor heads to the rafters with the wood...

Страница 10: ...the drywall in the home 9 Using the included drywall screws fasten the damper box to the drywall and the joist in the attic NOTE Remember that you must fasten the damper box to the ceiling joists AND drywall The purpose of this is to make sure the damper box stays in place when you are screwing in the grille If you do not fasten the damper box to the drywall the damper box will not stay in place w...

Страница 11: ...now complete NOTE Local building codes and standards must be adhered to in the installation of this unit NOTE Additional insulation can be added to the top of the damper box to provide additional sound dampening AVOID BACK DRAFTS Care should be taken to avoid back drafting combustion appliances that are installed in the conditioned space Whole house fans are capable of pulling large quantities of ...

Страница 12: ...e vertical adapter Place the vertical adapter with the T side up onto the damper box with the side that has only two flanges flush on the damper box 2 If you have studs spaced at 16 on center you will need to remove certain flanges on the damper box and vertical adapter Using a flat head screwdriver remove the two side flanges on the vertical adapter See Figure 1 3 Using a flat head screwdriver re...

Страница 13: ...tion 4 1 Single Speed Wiring for TRI PRO 1 5 1 For this installation you will need 2 2 wire Romex single gang retrofit box and an 8 Hour Timer Using the included wire nuts tie the black wire from the first 2 wire Romex from the power source to the black wire on the timer see Figure A 2 Using a wire nut tie the black wire on the 2 wire Romex from the fan to the red wire on the timer 3 Using a wire ...

Страница 14: ...ires together Tie your bare copper wire and green ground wires together 7 Carefully reinstall the handy box cover Power Source Black Tied Together with Black Red Switch Leg Single Speed Wiring Tie Black and Red Wires Together Whole House Fan Tie Ground Bare Copper Wires Together 14 2 Wire 8 HOUR 4 HOUR 2 HOUR 1 HOUR HOLD 14 2 Wire Tie White Common Wires Together Power Source Black Tied Together wi...

Страница 15: ...ower source to the black wire on the timer Tie the white common wire from the 2 wire power source to the white common wire on the timer and the white common wire from fan 4 Attach the red leg wire from the timer to the top gold screw on the left of the switch Install the switches and switch plate cover Power Source Black Tied Together with Black Red Switch Leg High Low Two Speed Wiring Tie Common ...

Страница 16: ... Using the 3 wire Romex from the first fan motor head attach the black wire to the 4th gold screw on the right and the red wire to the 3rd gold screw on the right of the switch Using the 2 wire Romex from the second fan motor head attach the black wire to the 2nd gold screw on the switch Attach the red wire from the 8 Hour Timer to the bottom black screw on the switch see Figure F 3 Using the 2 wi...

Страница 17: ...e nuts tie the black wires together for high speed Tie the red wires together for low speed Tie the remaining white common wires together Tie your bare copper wires and green ground wires together Carefully reinstall the handy box cover see Figure E Figure E Power Source Black Tied Together with Black Red Switch Leg Off High High Low Four Speed Wiring Tie Common Wires Together Red Low Speed Wire W...

Страница 18: ...wires are stripped Then using the included wire nuts tie the black wires together for high speed Cap the red wire from the motor as we will not be using it on this fan Then tie your white common wires together Lastly tie your bare copper wire and green ground wire together see Figure G Tie All Ground Bare Copper Wires Together Cap Red Wire Black Wires Together Common Wires Together Whole House Fan...

Страница 19: ...f 2 Cost of service calls to diagnose the cause of problems or the labor charge to un install any components 3 Product failure or damage due to faulty installtion abuse misuse unauthorized alteration to factory specs lack of maitenance or transportation damage 4 Shipping or postage for warranty claims D To obtain service under this warranty first contact the dealer where you purchased the equipmen...

Страница 20: ...FANS 43352 Business Park Drive Temecula CA 92590 PH 951 325 6340 QUIETCOOLSYSTEMS COM QuietCool is Proudly Designed and Built in California Fan Serial Number Information Retain for your records Serial number is required for warranty purposes ...

Отзывы: