Appendix A. Connection Diagrams
Power
Wall Transformer
24 VAC
Rain
Detect
ENET
24 VAC
Rain
Detect
ENET
Insert transformer leads into the terminal plug (shown at left)
then turn the tightening screw located on the top of the
terminal plug clockwise until tight. When both wires are
connected, connect the plug to the power terminal as shown.
Terminal Plug Side View
X
X
EtherRain 8
24 VAC
Rain
Detect
ENET
24 VAC
Rain
Sensor
ENET
Zone 1
Zone 4
Zone 2
Common
Zone 3
Zone 8
Zone 5
Zone7
Zone 6
EtherRain 7P
24 VAC
Rain
Detect
ENET
24 VAC
Rain
Detect
ENET
Zone 1
Zone 4
Zone 2
Common
Zone 3
Control
Zone 5
Zone7
Zone 6
To Pump Power Relay
or
Master Valve
C o m m o n