Troubleshooting
LF-100 User Guide
37
Fix
First check to see if you have a flat even media roll before you begin installation. An uneven
media roll will cause the job to misalign itself. If that checks out OK, then you will need to adjust
the tension force on the lamination module. To do this you must turn the two black knobs
located at the top the rubber roller assembly to adjust the tension force until you receive
satisfactory results. If needed, this may have to be done in conjunction with adjusting the clutch
tension on both the lamination core (If using lamination) and the material core using the
aluminum handles. Adjust the tension force at all three locations accordingly until you get the
perfect setting and the media is properly aligned.
Plotter Error “E01017 Hardware X Position Alarm Power off
then on”
Problem
The plotter displays an error “E01017 Hardware X Position Alarm Power off then on”.
Cause
The plotter will give you this error after starting a job in Virgo CM and the tensioner arm was not
set-up to begin with or the tensioner arm was positioned too high after turning on the lamination
module.
Note:
To set the tensioner arm properly, the arm must always be at a midpoint position or lower
before turning on the lamination module.
Fix
1.
To set-up the tensioner arm, first turn off lamination module.
Note:
The lamination module must be off for the next steps to work.
2.
Use the arrow buttons at the top of the control panel to manually feed the media forward
until the arm descends into the correct position. Correct position for the tensioner arm will
be midpoint or lower.
3.
Once Tensioner is in the correct position, turn ON lamination module.
If done successfully, the tensioner arm will automatically re-adjust itself thus activating
the unwinder motor.
4.
Restart Cutting Manager software.
Содержание LF-100
Страница 4: ...China 1F Bldg2 458 North Fu Te Road Shanghai Waigaoqiao F T Z 200131 Tel 86 21 5868 2809 quicklabel cn...
Страница 8: ...Installation and Setup LF 100 User Guide 8 3 Click Next 4 Click Next...
Страница 9: ...Installation and Setup LF 100 User Guide 9 5 Click Next 6 In process...
Страница 10: ...Installation and Setup LF 100 User Guide 10 7 Click Next 8 Click Finish 9 Click OK...
Страница 30: ...Operation LF 100 User Guide 30 Waste Removing Rewinding Module...